Acta otorrinolaringologica espanola

Cross-cultural Adaptation and Validation of the Spanish Version of the Generic Body-Focused Repetitive Behavior Scale-45 (GBS-45) for the Assessment of Rhinotillexomania.

Natalia Arango-Cabezas, María Jesús Rojas-Lechuga, Katherine Yuen-Ato, Paola Aguilera, Lucía Prieto, Ramón Moreno-Luna, Manuel Bernal-Sprekelsen, Steffen Moritz,

Rhinology and Skull Base Unit, Department of Otorhinolaryngology and Head and Neck Surgery, Hospital Clínic, IDIBAPS, CIBERES, Universitat de Barcelona, Spain. · Rhinology and Skull Base Unit, Department of Otorhinolaryngology and Head and Neck Surgery, Hospital Clínic, IDIBAPS, CIBERES, Universitat de Barcelona, Spain. Electronic address: mrojas@clinic.cat.

Observational

Key points

From the paper's conclusion
  • The Spanish version of the GBS-45 for rhinotillexomania is a reliable and valid instrument, useful for clinical assessment and follow-up in Spanish-speaking populations.

Abstract

INTRODUCTION: Body-focused repetitive behaviours (BFRBs) may lead to significant physical and psychosocial consequences. Rhinotillexomania is a common and underdiagnosed behaviour for which no validated Spanish-language instruments are currently available for specific assessment. The Generic Body-Focused Repetitive Behavior Scale-45 (GBS-45) is a transdiagnostic tool designed to assess the severity and functional impact of BFRBs. The aim of this study was to validate and cross-culturally adapt the rhinotillexomania-specific section of the GBS-45 for a Spanish-speaking population. MATERIALS AND METHODS: This prospective multicentre study included adult patients with nasal septal perforation secondary to rhinotillexomania (n = 29) and a healthy control group (n = 32). Cross-cultural adaptation was performed according to standardised methodology. Internal consistency was assessed using Cronbach's alpha. Test-retest reliability (1-2 weeks) was analysed using the intraclass correlation coefficient (ICC) and Pearson's correlation coefficient. Discriminant validity was assessed using the Mann-Whitney U test. RESULTS: The Spanish version demonstrated excellent internal consistency (α = 0.931 at baseline; α = 0.937 at retest). Temporal stability was high (overall ICC = 0.937; r = 0.939; 95% CI 0.899-0.964; p < 0.001). Significant differences were observed between cases and controls in the total score and across all specific items (p < 0.001). CONCLUSIONS: The Spanish version of the GBS-45 for rhinotillexomania is a reliable and valid instrument, useful for clinical assessment and follow-up in Spanish-speaking populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers