◆ Oral oncology2026-08-12

Radiation dose modulates plate complications in patients undergoing maxillo-mandibular reconstruction.

Micah K Harris, Jeff Shogan, Joshua D Smith, Kevin J Contrera, Shaum S Sridharan, Steven B Chinn, Anish Ghodadra, Ayoola Okuribido, Christopher Tyerech, Travis McCaw, Joseph Shields, Yvonne Mowery, Christopher Wilke, Sarah Ashmeg, Matthew E Spector

一句话结论 · In one sentence

Titanium reconstruction plates carry a high complication rate, with a threshold of > 60 Gy associated with a three-fold increase in complication risk. These findings suggest a need for alternative plating strategies or materials to reduce patient morbidity.

原始摘要(英文原文)· Original abstract
BACKGROUND: Despite carrying significant complication risk, titanium plates remain the standard-of-care in the reconstruction of segmental mandibulectomy defects. Radiation therapy (RT) is known to impair wound healing and cause dose perturbation at the metal-tissue interface. In this study, we sought to investigate the relationship between RT dosimetry and hardware-related complications. METHODS: A retrospective review of 99 patients who underwent segmental mandibulectomy with osseous free flap and titanium plate reconstruction between 2013 and 2022 was performed. Multivariable logistic and linear regression were performed to evaluate hardware-related complications, including plate exposure, fracture, screw loosening, and fistula/infection, adjusting for age, tumor stage, diabetes, and tobacco history. RESULTS: Overall, 60 patients (60.6 %) experienced at least one plate-related complication at a median of 11.2 months (range 0.33-93.1 months) and mean of 22.1 ± 15.8 months from surgery. Plate removal was required in 28.3 % of the cohort. Each 1 Gy of radiation conferred a 6.8 % increase in the odds of any plate complication (OR 1.07, 95 % CI 1.00-1.14, P = 0.037), with > 60 Gy predicting any plate complication (OR 3.07, 95 % CI 1.12-8.41, P = 0.03), plate removal (OR 3.13, 95 % CI 1.15-8.53, P = 0.026) and fistula or soft tissue infection (OR 2.99, 95 % CI 1.13-7.87, P = 0.027) after controlling for age, tumor stage, diabetes, and tobacco use. CONCLUSIONS: Titanium reconstruction plates carry a high complication rate, with a threshold of > 60 Gy associated with a three-fold increase in complication risk. These findings suggest a need for alternative plating strategies or materials to reduce patient morbidity.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Radiation dose modulates plate complications in patients undergoing maxillo-mandibular reconstruction. — 科研速览 Science Skim