Defining the optimal duration of remote home tonometry for accurate characterization of intraocular pressure fluctuation.
Michael S Jensen, Andy W Renschler, Catherine Johnson, Coy M Steel, Devin Eddington, Maria C Pizarro Peñaranda, Shashi Chaudhary B Optom, Natalie Hamilton,
John Moran Eye Center, Department of Ophthalmology & Visual Sciences at the University of Utah, Salt Lake City, UT. · Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD.
Key points
From the paper's conclusion- Remote tonometry provides clinically meaningful characterization of IOP metrics beyond traditional office-based measurements. Depending on the clinical context, seven to ten consecutive monitoring days consisting of measurements across each day are needed to represent a patient's true IOP pattern.
Abstract
PURPOSE: To determine the minimal duration of remote intraocular pressure (IOP) monitoring needed to yield accurate IOP fluctuation metrics in patients. DESIGN: Secondary modeling analysis of retrospective data, validated with a large national database. PARTICIPANTS: 397 patients from the Moran Eye Center and/or Wilmer Eye Institute and 1,579 patients from a MyEyes CorporationTM database who utilized an iCare HOME/HOME2 tonometer and recorded ≥3 measurements throughout each day over several consecutive days. METHODS: Bootstrapped progressive day-censorship analyses and exponential decay modeling were used to estimate the number of monitoring days required to achieve 95% of the maximal model-based reduction in error for IOP metrics, including mean, maximum, range, and standard deviation (SD). Ground truth for each metric was defined using all available measurements within each eye-specific monitoring period. Sensitivity analyses assessing the effects of diagnosis, treatment, and three daily IOP measurements were also completed. MAIN OUTCOME MEASURES: Mean absolute error (MAE) and mean relative error (MRE) for IOP mean, maximum, range, and SD; the number of monitoring days required to achieve 95% of the maximal model-based reduction in error. RESULTS: Across both datasets, approximately 6-7 monitoring days were required to achieve 95% of the modeled reduction in error for daily mean, maximum, range, and SD of IOP in the primary analysis. Sensitivity analyses demonstrated longer monitoring requirements in primary open-angle glaucoma (9.1-10.0 days) compared with glaucoma suspects (5.5-6.7 days), secondary open-angle glaucoma (6.4-8.0 days), and primary angle-closure glaucoma (7.8-8.3 days). Monitoring durations remained relatively consistent before and after selective laser trabeculoplasty (8.4-9.0 days) and Hydrus microstent implantation (6.0-6.8 days). Restricting measurements to only three daily IOP recordings throughout the day extended monitoring duration to approximately 10 days in the Moran/Wilmer dataset and longer in the MyEyes dataset. Additionally, 74.1% of peak IOP measurements occurred outside typical clinic hours. CONCLUSIONS: Remote tonometry provides clinically meaningful characterization of IOP metrics beyond traditional office-based measurements. Depending on the clinical context, seven to ten consecutive monitoring days consisting of measurements across each day are needed to represent a patient's true IOP pattern.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement between iCare HOME and Goldmann applanation tonometry: systematic review and meta-analysis.Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2026
- In-office and remote intraocular pressure metrics associated with visual field progression in treated open-angle glaucoma.Ophthalmology · 2026
- Detecting Intraocular Pressure Harmonic Frequencies in Glaucoma and the Sampling Targets Needed to Identify Them With Self-Tonometry.Investigative ophthalmology & visual science · 2026
- Comparison of Intraocular Pressure Measurements Using iCare Rebound Tonometry and Goldmann Applanation Tonometry: A Systematic Review and Meta-Analysis.Journal of glaucoma · 2026
- What Do Infrequent Goldmann Applanation Tonometry Measurements Reveal About Intraocular Pressure Profiles After Nonpenetrating Glaucoma Surgery?Translational vision science & technology · 2026
- The rise of modern tonometry: the evolution of intraocular pressure measurement.Expert review of medical devices · 2026