Absolute Myocardial Blood Flow via Single-Time-Point Imaging in PET and SPECT: Cross-Validation Against Dynamic 13N-Ammonia PET.
Mauro Namías, Aley Palau San Pedro, Laura Tatiana Pelegrina, Laura Calderón Brenner, Roberto Agüero, Roxana Campisi, Ricardo Geronazzo
Research and development department, Fundación Centro Diagnóstico Nuclear, Buenos Aires, Argentina. Electronic address: mnamias@fcdn.org.ar. · Medical physics department, Fundación Centro Diagnóstico Nuclear, Buenos Aires, Argentina.
Key points
From the paper's conclusion- The simplified STP approach provides reliable MBF and MFR estimates from standard static scans, showing strong agreement with dynamic 13N-Ammonia PET. By eliminating the requirement for full dynamic protocols, this method facilitates absolute flow quantification using existing conventional SPECT infrastructure.
Abstract
BACKGROUND: Quantitative assessment of myocardial blood flow (MBF) and flow reserve (MFR) is clinically superior to relative imaging but limited by dynamic scanning requirements. We evaluated a novel single-time-point (STP) method to estimate MBF from a single static image using a population-based power law model of the arterial input function. METHODS: The STP model was optimized using retrospective dynamic 13N-Ammonia PET/CT data (n = 90) and prospectively validated in 31 symptomatic patients undergoing both dynamic 13N-Ammonia PET (reference) and conventional 99mTc-MIBI SPECT/CT (leave-one-patient-out cross-validation). STP estimates were compared against dynamic PET via correlation and Bland-Altman analyses. RESULTS: The STP model demonstrated stable performance across a wide post-injection window in PET. For 99mTc-MIBI SPECT, reproducibility coefficients for stress MBF (44%), rest MBF (58%) and MFR (67%) were comparable to PET test-retest literature. SPECT MBF 95% limits of agreement (range: 1.5 mL/g/min) approached or exceeded reported dynamic CZT-SPECT benchmarks. Technical acquisition delays were the primary source of model degradation. CONCLUSION: The simplified STP approach provides reliable MBF and MFR estimates from standard static scans, showing strong agreement with dynamic 13N-Ammonia PET. By eliminating the requirement for full dynamic protocols, this method facilitates absolute flow quantification using existing conventional SPECT infrastructure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Myocardial blood flow quantification by widely available conventional nai SPECT improves detection of hemodynamically significant coronary stenosisEuropean Heart Journal · 2026
- Evaluation of Myocardial Blood Flow Using 18F-flurpiridaz PET: Established Applications with Pharmacologic Stress and Roadmap for Exercise Stress Implementation.Current cardiology reports · 2026
- Quantitative and semi-quantitative comparison of myocardial blood flow between 99mTc-tetrofosmin and 99mTc-sestamibi: based on continuous rapid dynamic imaging technology using cadmium-zinc-telluride cardiac single-photon emission computed tomography.Quantitative imaging in medicine and surgery · 2026
- Inter-Observer Reliability in Myocardial Blood Flow Measurement Using Rb-82-PET/CT.Tomography (Ann Arbor, Mich.) · 2026
- The Effect of Motion Correction on Quantitative Perfusion Indices and Threshold-Based Interpretation in 13N-Ammonia Dynamic PET Myocardial Perfusion Imaging.Diagnostics (Basel, Switzerland) · 2026
- The prognostic value of quantitative myocardial blood flow and flow reserve by dynamic CZT-SPECT for major adverse cardiovascular events.European journal of nuclear medicine and molecular imaging · 2026