Catheter-related bloodstream infection in non-tunneled hemodialysis access: A prospective 12-month study.
Rafael Figueiredo, Bernardo Fernandes, Luís Coentrão, Edgar Botelho-Moniz, Patrícia Martins, Manuel Pestana
Nephrology Department, Unidade Local de Saúde de São João, Porto, Portugal. Electronic address: rafaelhenriquesfigueiredo@gmail.com. · Nephrology Department, Unidade Local de Saúde de São João, Porto, Portugal.
Key points
From the paper's conclusion- CRBSI incidence aligns with international benchmarks and is front-loaded to the first two weeks of catheter use. These data support expedited conversion to definitive access to minimize early exposure, rigorous diagnostic bundles to avoid unnecessary exchanges and empirical regimens with gram-negative activity tailored to local epidemiology.
Abstract
BACKGROUND: Catheter-related bloodstream infection (CRBSI) is a major complication of temporary, non-tunneled hemodialysis (HD) catheters, yet contemporary incidence data are scarce. METHODS: In a 12-month prospective cohort (1 February 2023-31 January 2024), we followed all adult inpatients who received a non-tunneled dual-lumen HD catheter until device removal. At removal, we obtained paired blood cultures from each lumen, a peripheral culture and a semi-quantitative tip culture. CRBSI was defined by the concordant growth of the same organism in ≥3 of the 4 cultures. The primary outcome was the incidence of CRBSI per 1000 catheter-days; secondary outcomes included colonization rate and pathogen distribution. RESULTS: Ninety-four patients (50% male; mean age, 67.6±14.1 years) carried 108 catheters, resulting in 1550 catheter-days. Right femoral insertion predominated (74%); median dwell time was 12 days, and 39% of catheters remained in situ >15 days. Systemic antibiotics were given for 56 catheters (51.9%) within the preceding 15 days. Cultures were sterile for 67 catheters (62.0%) and showed colonization without bacteremia in 30 (27.8%; 19.4/1000 catheter-days, 95% CI 13-28). Six catheters (5.6%) met CRBSI criteria, giving an incidence of 3.87/1000 catheter-days (95% CI 1.4-8.4). All CRBSI episodes occurred within 15 days of insertion. Isolates were Pseudomonas aeruginosa (n=3), Enterococcus faecalis (n=2) and Klebsiella oxytoca (n=1). Only 5 of 21 catheters (24%) removed for presumed infection were confirmed CRBSI; no infection-related deaths occurred. CONCLUSION: CRBSI incidence aligns with international benchmarks and is front-loaded to the first two weeks of catheter use. These data support expedited conversion to definitive access to minimize early exposure, rigorous diagnostic bundles to avoid unnecessary exchanges and empirical regimens with gram-negative activity tailored to local epidemiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Profile and Outcomes of Culture-Negative Catheter-Related Bloodstream Infections in Hemodialysis Patients: A Cross-Sectional StudyInternational Journal of Drug Delivery Technology · 2026
- Catheter-Related Bloodstream Infection (CRBSI) akibat Methicillin-Resistant Staphylococcus aureus (MRSA) pada Pasien Hemodialisis: Laporan KasusMEDICINUS · 2026
- An 11-Year Population-Based Evaluation of Bloodstream Infections in Adults Undergoing Hemodialysis in Southeastern MinnesotaAntibiotics · 2026
- Twice isolated, not twice ignored: Bacillus cereus catheter-related bloodstream infection in a haemodialysis patient.Indian journal of medical microbiology · 2026
- SEQuential tUnneled Catheters and Infective Events in haemodiaLysis: A Five-Year Retrospective Cohort Study (SEQUEL Study).PloS one · 2026
- Long-Term Use of Non-tunneled Centrally Inserted Central Venous Catheters for Home Parenteral Nutrition in Bedridden Patients: A Retrospective Cohort Study.Cureus · 2026