Post-complexation water dilution arrests PEI:DNA polyplex growth and widens the operational window for transient transfection.
Laia Miranda, Sara Rodriguez-Conde, Michael Thomas, Andrea Ducci, Martina Micheletti
Department of Biochemical Engineering, University College London, London, UK. Electronic address: laia.garrido.22@ucl.ac.uk. · Cell Culture & Fermentation Sciences, BioPharmaceutical Development, BioPharmaceuticals R&D, AstraZeneca, Cambridge, UK. Electronic address: sara.rodriguezconde@astrazeneca.com.
Key points
From the paper's conclusion- The data support that post-complexation water dilution reduces the sensitivity of PEI-mediated TGE to incubation time variability, with potential application to large-scale bioreactor operations.
Abstract
Scalability of polyethyleneimine (PEI) mediated transient gene expression (TGE) is limited by time-dependent growth of PEI:DNA polyplexes in saline buffers, which narrows the usable incubation window and amplifies run-to-run variability as preparation and addition delays accumulate during scale-up. In this study, we introduce a simple post-complexation size lock strategy to arrest polyplex size. Complexes are first formed in saline to achieve biologically effective dimensions and then rapidly diluted with water to reduce nominal ionic strength to approximately 50mM or 60mM for the 150mM or 600mM NaCl formulations, respectively, arresting further growth. Dynamic light scattering (DLS) demonstrated that dilution preserved the hydrodynamic diameter at the quench time for at least 60min. In a shake-flask CHO culture transfected with dual plasmid for monoclonal antibody (mAb) expression, extending conventional saline incubation from 4 to 20min reduced mAb titer from 345 to 166mg/L and QP from 7.0 to 3.6pg/cell·day, whereas size-locked complexes maintained optimal output (mAb 352mg/L; QP 7.13pg/cell·day). Preliminary biological validation in the mAb system was performed at 250mL stirred-tank bioreactor scale (n = 2 per condition). Additionally, arrested polyplex growth following dilution was also confirmed via DLS across alternative TGE formats, including green fluorescent protein (GFP, 1 plasmid), adeno-associated viral vectors (AAV, 3 plasmids), and lentiviral vectors (LV, 4 plasmids). The data support that post-complexation water dilution reduces the sensitivity of PEI-mediated TGE to incubation time variability, with potential application to large-scale bioreactor operations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- N/P-Dependent DNA Complexation, Transfection, and Cytotoxicity of Imine-Linked Low-Molecular-Weight PEI Polyplexes.International journal of molecular sciences · 2026
- DNA condensation by 4-arm PEG-histidine/lysine peptide polyplexes: Tuning transfection and biocompatibility.International journal of biological macromolecules · 2026
- Process Design for Small-Scale Production of PEGDA-NVP Hydrogel Nanoparticle Emulsions for Therapeutic Applications.ACS omega · 2026
- Steric Stabilization of Lipid Nanoparticles by Sequence-Defined Polymer−Lipids Enhances Gene ExpressionACS Applied Nano Materials · 2026
- Optimized polyethylene glycol precipitation yields high-purity, biologically active mouse liver tissue exosomes.Molecular biology reports · 2026
- Post-transfection Collection Timing Determines Plasmid DNA Encapsulation Efficiency in Extracellular VesiclesCellular and Molecular Bioengineering · 2026