Multiple sclerosis and related disorders

Comparative performance of 7T MRI sequences for central vein sign detection in multiple sclerosis: a prospective study.

Xinyao Liu, Ying Yang, Zhe Zhang, Wanlin Zhu, Qin Xu, Ai Guo, Yunyun Duan, De-Cai Tian,

China National Clinical Research Center for Neurological Diseases, Beijing Tiantan Hospital, Capital Medical University, Beijing, China; Tiantan Neuroimaging Center of Excellence, China National Clinical Research Center for Neurological Diseases, Beijing Tiantan Hospital, Beijing, China. · Department of Neurology, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China.

Observational · n=20

Key points

From the paper's conclusion
  • Our study indicates that conventional, widely available GRE T2* and SWI perform comparably to 3D EPI T2* for CVS detection at 7T MRI.

Abstract

BACKGROUND: The central vein sign (CVS) has been incorporated into the 2024 McDonald criteria for multiple sclerosis (MS) diagnosis. However, the optimal MRI sequence for detecting CVS at 7T remains unclear due to limited direct comparisons. This study aimed to perform a head-to-head comparison of gradient-recalled echo (GRE T2*), susceptibility-weighted imaging (SWI), and 3D echo-planar imaging (3D EPI T2*) sequences for CVS detection in MS patients using 7T MRI. MATERIALS AND METHODS: 20 participants with MS were prospectively recruited from the Chinese National Registry of Neuroinflammatory Diseases (CNRID) and scanned on a 7T MRI scanner using three sequences. CVS-positive lesions were independently assessed by two blinded raters. Lesion-level detection rates and inter-/intra-rater reliability were evaluated using the Friedman test and Cohen's kappa. RESULTS: A total of 1411 MS lesions were analyzed. No significant differences were found in CVS detection rates across the three sequences (GRE T2*: 780; SWI: 771; 3D EPI T2*: 777; P = 0.082). All sequences showed excellent inter-rater (κ ≥ 0.935) and intra-rater (κ ≥ 0.961) agreement. Slightly lower detection with 3D EPI T2* was attributed to resolution limitations, while SWI missed lesions mainly due to insufficient tissue contrast. CONCLUSIONS: Our study indicates that conventional, widely available GRE T2* and SWI perform comparably to 3D EPI T2* for CVS detection at 7T MRI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers