Whole-body fetal 3D CINE MRI with low flip angle balanced steady-state free precession acquisition within the specific absorption rate limit at 1.5 T.
Tatsuhiro Wada, Koji Sagiyama, Hoshinori Kanazawa, Chiaki Tokunaga, Yuya Saito, Kei Nishikawa, Koji Kobayashi, Yukiyo Shimada,
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Japan. Electronic address: wada.tatsuhiro.285@m.kyushu-u.ac.jp. · Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Japan.
Key points
From the paper's conclusion- Low-FA 3D bSSFP CINE MRI at 1.5 T enables visualization of whole-body fetal movements within the SAR limit at a temporal resolution of approximately 320 msec.
Abstract
PURPOSE: To develop a three-dimensional (3D) CINE magnetic resonance imaging (MRI) sequence for assessing whole-body fetal movements within the specific absorption rate (SAR) limit, and to evaluate its clinical feasibility. METHODS: A 3D balanced steady-state free precession (bSSFP) CINE MRI sequence was developed at 1.5 T within a whole-body averaged SAR of ≤ 2 W/kg. Half-scan artifacts (zero-valued pixels) and flip angle (FA) effects on signal intensity and contrast were assessed in phantoms. Seventeen fetal examinations (14 with the final protocol) were evaluated visually by two readers and by the contrast-to-noise ratio (CNR) between fetal tissues and amniotic fluid. RESULTS: Zero-valued pixels appeared with the half-scan technique and increased as the half-scan factor decreased. The contrast between the phantoms was greater at higher FAs. Reducing the FA to 25° allowed a shorter TR within the SAR limit, enabling a 3D slab placed over the fetus to be acquired without the half-scan technique at a temporal resolution of approximately 320 msec (whole-body SAR, 1.59-1.94 W/kg). The CNRs between the amniotic fluid and the brain, lung, abdomen and limbs were 24.1 ± 10.6, 23.1 ± 12.8, 27.3 ± 14.3 and 30.9 ± 9.2, respectively. With the final protocol, both readers identified fetal movement in 11 of 14 examinations (κ = 1.00), and fold-over artifacts impaired the evaluation in two and three examinations, respectively. CONCLUSION: Low-FA 3D bSSFP CINE MRI at 1.5 T enables visualization of whole-body fetal movements within the SAR limit at a temporal resolution of approximately 320 msec.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region-Optimized Virtual Coils (ROVir).Magnetic resonance in medicine · 2026
- Free‐Breathing Dynamic, Regularized, Adaptive Cluster Optimization ( DRACO ) Cine Cardiac MRI in Atrial FibrillationJournal of Magnetic Resonance Imaging · 2026
- Diffusion MRI-Based Fetal Thermometry Using Cerebrospinal Fluid: A Translational Feasibility Study.Journal of magnetic resonance imaging : JMRI · 2026
- Assessment and validation of the established free-running framework for cardiac function by magnetic resonance imaging at 1.5T (FAST-CMR): an international multi-center, multi-vendor study.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- Automated reconstruction of dynamic 2D fetal cardiac MRI using deep learning in late third-trimester fetuses.European journal of radiology · 2026
- Motion-Robust Approach for 4D Cardiac Cine Using 2D Real-Time Acquisitions and Slice-to-Volume Reconstruction.Magnetic resonance in medicine · 2026