Magnetic resonance imaging

Whole-body fetal 3D CINE MRI with low flip angle balanced steady-state free precession acquisition within the specific absorption rate limit at 1.5 T.

Tatsuhiro Wada, Koji Sagiyama, Hoshinori Kanazawa, Chiaki Tokunaga, Yuya Saito, Kei Nishikawa, Koji Kobayashi, Yukiyo Shimada,

Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Japan. Electronic address: wada.tatsuhiro.285@m.kyushu-u.ac.jp. · Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Japan.

Key points

From the paper's conclusion
  • Low-FA 3D bSSFP CINE MRI at 1.5 T enables visualization of whole-body fetal movements within the SAR limit at a temporal resolution of approximately 320 msec.

Abstract

PURPOSE: To develop a three-dimensional (3D) CINE magnetic resonance imaging (MRI) sequence for assessing whole-body fetal movements within the specific absorption rate (SAR) limit, and to evaluate its clinical feasibility. METHODS: A 3D balanced steady-state free precession (bSSFP) CINE MRI sequence was developed at 1.5 T within a whole-body averaged SAR of ≤ 2 W/kg. Half-scan artifacts (zero-valued pixels) and flip angle (FA) effects on signal intensity and contrast were assessed in phantoms. Seventeen fetal examinations (14 with the final protocol) were evaluated visually by two readers and by the contrast-to-noise ratio (CNR) between fetal tissues and amniotic fluid. RESULTS: Zero-valued pixels appeared with the half-scan technique and increased as the half-scan factor decreased. The contrast between the phantoms was greater at higher FAs. Reducing the FA to 25° allowed a shorter TR within the SAR limit, enabling a 3D slab placed over the fetus to be acquired without the half-scan technique at a temporal resolution of approximately 320 msec (whole-body SAR, 1.59-1.94 W/kg). The CNRs between the amniotic fluid and the brain, lung, abdomen and limbs were 24.1 ± 10.6, 23.1 ± 12.8, 27.3 ± 14.3 and 30.9 ± 9.2, respectively. With the final protocol, both readers identified fetal movement in 11 of 14 examinations (κ = 1.00), and fold-over artifacts impaired the evaluation in two and three examinations, respectively. CONCLUSION: Low-FA 3D bSSFP CINE MRI at 1.5 T enables visualization of whole-body fetal movements within the SAR limit at a temporal resolution of approximately 320 msec.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers