Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland; Geneva University, Geneva, Switzerland; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland. Electronic address: sana.boudabbous@hug.ch. · Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland. Electronic address: david.branco@hug.ch.

Review

Key points

From the paper's conclusion
  • 7 T knee MRI is feasible and potentially impactful in specific indications; however, stronger comparative data, protocol harmonization, and quantitative validation are needed.

Abstract

BACKGROUND: Ultra-high-field, 7 Tesla (T) MRI provides higher signal-to-noise ratio (SNR) and enables high-resolution 3D and quantitative imaging. Its role in musculoskeletal (MSK) knee imaging is emerging but not yet standardized. PURPOSE: To review current 7 T knee MRI techniques and evidence, detail key technical/physics considerations, and to report a single-center clinical experience through a descriptive study. METHODS: Up to date narrative synthesis of the literature organized by qualitative (morphologic) and quantitative applications, complemented by experience from a retrospective single-center series of consecutive 7 T knee examinations. RESULTS: Literature shows that 7 T imaging can improve conspicuity of cartilage, meniscus, ligaments, and bone microarchitecture with isotropic 3D acquisitions; quantitative methods (T2/T2*, Ultrashort Echo Time (UTE), Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST), 23Na, T1rho) show promise but require rigorous B0/B1 correction and Specific Absorption Rate (SAR) management. Our experience demonstrated that 7 T imaging was clinically feasible and well tolerated in a cohort of 131 patients (mean age 33.8 ± 10.5 years ranging from 16 to 63 years) and provided a potential and a subjective increase in diagnosis confidence in selected scenarios, particularly in postoperative meniscus assessment and conservative ACL follow-up. CONCLUSION: 7 T knee MRI is feasible and potentially impactful in specific indications; however, stronger comparative data, protocol harmonization, and quantitative validation are needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers