Magnetic resonance imaging

Integrated deep learning reconstruction combining phase correction, denoising, and super-resolution for prostate diffusion-weighted imaging.

Noriko Nishioka, Maki Onodera, Daisuke Kato, Satonori Tsuneta, Noriyuki Fujima, Ryuji Matsumoto, Takashige Abe, Jihun Kwon,

Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, N14 W5, Kita-ku, Sapporo 060-8648, Japan; Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15 W7, Kita-ku, Sapporo 060-8638, Japan. Electronic address: largo.cantabile@gmail.com. · Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, N14 W5, Kita-ku, Sapporo 060-8648, Japan; Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15 W7, Kita-ku, Sapporo 060-8638, Japan.

Computational · n=47

Key points

From the paper's conclusion
  • Integrated DLR improved prostate DWI image quality and lesion visibility compared with CS and Denoising DLR, potentially facilitating visual assessment of prostate DWI.

Abstract

OBJECTIVE: To evaluate integrated deep learning reconstruction (Integrated DLR), which combines phase correction, denoising, and super-resolution, for prostate diffusion-weighted imaging (DWI) by comparing it with compressed sensing (CS) and deep learning-based denoising reconstruction (Denoising DLR). METHODS: This single-center, retrospective study included 47 patients scanned on a single-vendor 3-T system. Three DWI datasets were reconstructed from identical raw data using CS, Denoising DLR, and Integrated DLR. Two radiologists rated overall image quality, noise, artifact, and prostate delineation. Apparent signal-to-noise ratio (SNR) was assessed in all patients. In 21 patients with pathologically confirmed prostate cancer, we assessed lesion conspicuity, lesion localization/anatomical relationship, Prostate Imaging Reporting and Data System (PI-RADS) version 2.1 DWI scores, apparent lesion contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC). Comparisons were performed using Friedman tests followed by Bonferroni-corrected Wilcoxon signed-rank tests. RESULTS: Scores for overall image quality, noise, and prostate delineation were highest with Integrated DLR, followed by Denoising DLR and CS, for both readers (all p < 0.001); apparent SNR showed the same pattern (p < 0.001). Artifact scores did not differ among methods. Lesion conspicuity differed among methods for Reader 2 (p = 0.044) but not for Reader 1 (p = 0.199), whereas Integrated DLR yielded the highest lesion localization/anatomical relationship scores for both readers (both p < 0.001). Integrated DLR also yielded the highest apparent CNR and lesion ADC (both p < 0.001), while PI-RADS DWI scores were unchanged. CONCLUSION: Integrated DLR improved prostate DWI image quality and lesion visibility compared with CS and Denoising DLR, potentially facilitating visual assessment of prostate DWI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers