Magnetic resonance imaging

Correlation between the IVIM-MRI based tissue perfusion parameters and blood flow index measured by diffuse correlation spectroscopy.

Neda Mogharari, Kamil Lipinski, Stanislaw Wojtkiewcz, Adam Liebert, Michal Kacprzak

Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Poland. Electronic address: nmogharari@ibib.waw.pl. · Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Poland; Institute of Radioelectronics and Multimedia Technology, Faculty of Electronics and Information Technology, Warsaw University of Technology, Poland.

Key points

From the paper's conclusion
  • Therefore, further studies with larger cohorts and different experimental protocols are required to better characterize the correlation between the IVIM- and DCS-derived parameters under varying perfusion conditions.

Abstract

Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) technique evaluates the microstructure and microvascular blood perfusion of biological tissues. IVIM-derived pseudo-diffusion coefficient (Dfast) quantifies the perfusion-related motion of blood within the tissue microvascular and is related to the mean squared displacement of water molecules in time. Diffuse correlation spectroscopy (DCS) is a noninvasive optical technique to monitor the microvascular blood flow changes. DCS-derived blood flow index (BFIDCS) is proportional to mean squared displacement of the red blood cells in time, thereby enabling comparison to Dfast. To evaluate the correlation between Dfast and BFIDCS, controlled muscle-occlusion tests were performed on five healthy volunteers, with five leg and four forearm datasets. In response to muscle occlusion, the BFIDCS decreased, whereas the mean Dfast increased, leading to no positive correlation between these parameters (rrm: repeated measures correlation, rrm=-0.219,95%CI:-0.724to0.438 in leg occlusion and rrm=-0.567,95%CI:-0.894to0.155, in forearm occlusion). The IVIM data were of adequate quality (median voxelwise signal to noise ratio at b = 0: 25-57), however the voxelwise coefficient of variation CVvoxels of the Dfast (median within-subjects CVvoxels in the leg: 210.3% and in forearm: 160.9%) were imprecise. The disagreement between the IVIM- and DCS-derived parameter responses is therefore specific to the applied protocol, and its cause remains unresolved. Therefore, further studies with larger cohorts and different experimental protocols are required to better characterize the correlation between the IVIM- and DCS-derived parameters under varying perfusion conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers