Measurement-derived residual-risk verification through four-way k-space partitioning in self-supervised accelerated brain MRI.
Ransford Silas Osei, Frank Osei, Stephen Obeng Ampadu
Independent Researcher, P.O. Box 8, New Tafo-Akim, Ghana. Electronic address: silasransfordosei@gmail.com. · All Nations University, Koforidua, Ghana.
Key points
From the paper's conclusion- We developed a measurement-derived verification framework that partitions acquired k-space into four roles: reconstruction input, self-supervised reconstruction-loss evaluation, residual-risk learning, and reserved verification.
Abstract
Self-supervised accelerated MRI reconstruction reduces dependence on fully sampled training targets, but it does not inherently provide a separate basis for verifying whether reconstructed image content remains locally consistent with acquired measurements. We developed a measurement-derived verification framework that partitions acquired k-space into four roles: reconstruction input, self-supervised reconstruction-loss evaluation, residual-risk learning, and reserved verification. Residuals from the reserved measurements were transformed into spatial residual-risk targets using density-compensated adjoint projection, probe-based gain normalization, anatomical support weighting, percentile scaling, and logarithmic compression. Using fastMRI brain multicoil data, we evaluated 201 training, 40 calibration, and 40 AXT2 test volumes, comprising 636 test slices and 999,792 sampled pixels. The primary Full-CNN achieved AUPRC 0.8348, mean absolute error 0.0834, Spearman correlation 0.9389, and AUROC 0.9818. The secondary A4-CNN achieved AUPRC 0.8452 with similar scale and rank agreement. MRI-volume intervals achieved at least 90% sampled-location coverage in 39 of 40 test volumes for both predictors. AUPRC declined and MAE increased with fewer reserved measurements and under AXFLAIR sequence shift. Residual-risk maps showed moderate correspondence with fully sampled reference error and differed from the tested predictive-variance measures. The framework provides a measurement-derived verification layer for assessing local residual inconsistency in self-supervised accelerated MRI without requiring fully sampled development targets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty-weighted dual-domain consistency for self-supervised accelerated MRI reconstruction.Biomedical physics & engineering express · 2026
- CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout.Medical image analysis · 2026
- Self‐supervised multi‐contrast MRI reconstruction via mask‐guided frequency‐domain fusionMedical Physics · 2026
- Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRIarXiv · 2026
- Self-supervised reconstruction framework via motion- and physics-informed learning for four-dimensional magnetic resonance fingerprinting.Medical image analysis · 2026
- Undersampled K-space information recovery with long-range temporal memory for multi-coil MRI reconstruction.Computer methods and programs in biomedicine · 2026