Design of a power independent of number of slices presaturated ultrashort echo time sequence for accelerated short-T2 imaging.

Jason A Reich, Erin L MacMillan, Rebecca E Feldman

Department of Computer Science, Mathematics, Physics and Statistics, University of British Columbia, Kelowna, BC, Canada. Electronic address: jareich@alum.ubc.ca. · UBC MRI Research Centre, Department of Radiology, University of British Columbia, Vancouver, BC, Canada; Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada. Electronic address: erin.macmillan@ubc.ca.

Key points

From the paper's conclusion
  • We implemented a novel sequence - the power independent of number of slices (PINS) presaturated UTE (PINS-UTE) sequence - that combines SMS and UTE techniques to increase flexibility in field-of-view and resolution, and reduce scan times for short-T2 imaging.

Abstract

Simultaneous multi-slice (SMS) techniques have reduced magnetic resonance imaging scan times, but they are challenging to integrate into ultrashort echo time (UTE) sequences. We implemented a novel sequence - the power independent of number of slices (PINS) presaturated UTE (PINS-UTE) sequence - that combines SMS and UTE techniques to increase flexibility in field-of-view and resolution, and reduce scan times for short-T2 imaging. The PINS-UTE sequence begins with a PINS prepulse and spoiler gradients to presaturate the magnetization profile. Next, a non-selective pulse is used to simultaneously excite six slices and enable UTE data acquisition with an echo time of 0.2 ms. Slice profiles were investigated and images of the skull were acquired in vivo at 3 T. The unwanted signal between the slices was minimized with a prepulse flip angle of 125°. The sequence was used to image a field-of-view of 220 × 220 × 168 mm3 with resolutions of 1.20 × 1.20 × 4.0 and 0.60 × 0.60 × 4.0 mm3 in scan times of 2 min 45 s and 5 min 30 s, respectively. These scan times are reduced by factors of 1.4 and 2.8, respectively, as compared to those of 3D UTE sequences with the same repetition time, in-plane field-of-view, and in-plane resolutions. The scan times of the PINS-UTE sequence may be further reduced by imaging fewer slices with a slice gap. As compared to half-pulse 2D UTE sequences, the PINS-UTE sequence is expected to reduce scan times by up to a factor of 12. The PINS-UTE sequence may be applied to accelerate the imaging of tendons, ligaments, and bone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers