Toward rapid MR-based assessment of osteoporosis in the lumbar spine - Acceleration of IR-UTE imaging for bound water quantification in trabecular bone at 1.5 T.

Philipp Hans Nunn, Oliver Schad, Natalie Hasenauer, Jan-Peter Grunz, Philipp Gruschwitz, Henner Huflage, Sebastian Scheidel, Thorsten Alexander Bley,

Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany. Electronic address: Nunn_P1@ukw.de. · Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.

Key points

From the paper's conclusion
  • BW quantification in lumbar spine trabecular bone using IR-UTE at 1.5 T is feasible, and BWPD values differed between the evaluated young healthy volunteers and the patient with OP. Transfer learning via DnCNN fine-tuning demonstrated the potential to accelerate IR-UTE-based BW analysis in trabecular bone while preserving agreement with reference acquisitions.

Abstract

PURPOSE: This study aimed to explore the feasibility of accelerating inversion recovery-prepared ultra-short echo time (IR-UTE)-based bound water (BW) quantification in trabecular bone of lumbar vertebrae at 1.5 T. METHODS: A 3D radial IR-UTE sequence for selective BW imaging at 1.5 T was implemented using Pulseq to acquire data from the lumbar spine in seven young healthy volunteers and three patients with osteoporosis (OP). Reconstructions from seven reference datasets (30-min acquisition time) and retrospectively undersampled subsets (acceleration factor R = 6) derived therefrom were subsequently paired, yielding 126 input-target pairs for fine-tuning a denoising convolutional neural network (DnCNN) pre-trained on IR-UTE images of the knee. Scalar image quality metrics were calculated, and trabecular BW proton density (BWPD) in L1-L4 was determined using the remaining datasets from two young healthy volunteers and one patient with OP, including an additional prospectively accelerated scan in one healthy volunteer. RESULTS: Applying the DnCNN enhanced agreement with the reference, as indicated by improved scalar image metrics and reduced bias in BWPD values. Trabecular BWPD, thus derived, was higher in the young healthy volunteers than in the patient with OP (mean across L1-L4 [mol 1H/L]: 2.307 and 2.378, the latter 2.384 prospectively, vs. 0.664). CONCLUSION: BW quantification in lumbar spine trabecular bone using IR-UTE at 1.5 T is feasible, and BWPD values differed between the evaluated young healthy volunteers and the patient with OP. Transfer learning via DnCNN fine-tuning demonstrated the potential to accelerate IR-UTE-based BW analysis in trabecular bone while preserving agreement with reference acquisitions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers