Trends in molecular medicine

Vascular-device suit concordance: a tri-ecological framework for eco-rebalancing.

Lingsen You, Yaxuan Li, Yuchen Luo, Qiang Cheng, Liuliu Feng, Li Shen, Junbo Ge

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China; National Clinical Research Center for Interventional Medicine, Shanghai 200032, China; Oriental Panvascular Devices Innovation College, University of Shanghai for Science and Technology (USST), Shanghai 200093, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China; NHC Key Laboratory of Ischemic Heart Diseases, Shanghai 200032, China. · Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China; National Clinical Research Center for Interventional Medicine, Shanghai 200032, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China; NHC Key Laboratory of Ischemic Heart Diseases, Shanghai 200032, China.

Key points

From the paper's conclusion
  • We propose eco-rebalancing as a tri-ecological framework in which durable device performance depends on coordinated recovery across three domains: the mechanical, cellular, and physicochemical-immune ecologies.

Abstract

Panvascular intervention can restore lumen patency, exclude structural defects, or replace diseased valves, but procedural success does not reestablish ecological stability within the treated vessel. We propose eco-rebalancing as a tri-ecological framework in which durable device performance depends on coordinated recovery across three domains: the mechanical, cellular, and physicochemical-immune ecologies. Vascular-device suitcordance denotes the spatiotemporal match between a device's mechanical behavior, biological interface, and material persistence, and the healing trajectory of a specific vascular bed, lesion, and patient; we introduce the Suitcordance Score (Su-Score) as a conceptual metric of that match. This perspective reinterprets restenosis, thrombosis, fibrosis, calcification, and structural degeneration as signatures of incomplete eco-rebalancing, providing a translational basis for device design and patient-device matching.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers