Journal of microbiological methods

MALDI-TOF MS and FT-IR spectroscopy for typing vancomycin-resistant Enterococcus faecium: Comparison with PFGE in a hospital outbreak collection.

Dominika Seliga-Gąsior, Dominika Lachowicz, Wanda Kamińska, Edyta Podsiadły

Microbiological Laboratory, University Center for Laboratory Medicine, University Medical Center, Medical University of Warsaw, 1a Banacha Str., Warsaw 02-097, Poland. Electronic address: dominika.gasior@uckwum.pl. · Microbiological Laboratory, University Center for Laboratory Medicine, University Medical Center, Medical University of Warsaw, 1a Banacha Str., Warsaw 02-097, Poland; Department of Dental Microbiology, Medical University of Warsaw, 1a Banacha Str., Warsaw 02-097, Poland.

Key points

From the paper's conclusion
  • Twenty-two VREfm isolates collected during a hospital outbreak investigation (November 2016-February 2017) were analyzed by MALDI-TOF MS and FT-IR spectroscopy; PFGE was performed for 18 isolates.

Abstract

Rapid and reliable strain typing is essential for investigating hospital outbreaks of vancomycin-resistant Enterococcus faecium (VREfm). We evaluated MALDI-TOF MS and Fourier-transform infrared (FT-IR) spectroscopy as rapid typing approaches, and compared the resulting strain classifications with those obtained by pulsed-field gel electrophoresis (PFGE). Twenty-two VREfm isolates collected during a hospital outbreak investigation (November 2016-February 2017) were analyzed by MALDI-TOF MS and FT-IR spectroscopy; PFGE was performed for 18 isolates. Comparative analysis included 16 isolates with complete and interpretable results for all three methods. Concordance and discriminatory power were assessed using the Adjusted Rand Index (ARI) and Simpson's Index of Diversity (SID). MALDI-TOF MS identified six types among 21 classifiable isolates, FT-IR identified five clusters, and PFGE identified five major pulsotypes, with the predominant pulsotype A divided into closely related subtypes A1 and A2. In the 16-isolate comparative dataset, MALDI-TOF MS reproduced the PFGE subtype classification (ARI = 1.000; SID = 0.683), whereas FT-IR, using a dataset-specific cut-off of 0.154, grouped A1 and A2 together (ARI = 0.692; SID = 0.533). When A1 and A2 were considered variants of the same major pulsotype, FT-IR showed complete concordance with PFGE within this subset (ARI = 1.000). Epidemiological reconstruction supported a predominant Onco-Hematology cluster and a separate epidemiologically linked Neonatal cluster. MALDI-TOF MS reflected finer PFGE subtype-level differentiation, whereas FT-IR corresponded to the broader major-pulsotype structure. Both methods may have potential as preliminary typing approaches in VREfm outbreak investigations, but their results require epidemiological interpretation, while WGS remains preferable when high-resolution assessment of genomic relatedness is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers