Journal of microbiological methods

Development of a multiplex real-time polymerase chain reaction assay for Clostridium perfringens enterotoxin genes and the species-specific alpha-toxin gene.

Shinya Yonogi, Tetsuya Harada, Masashi Kanki, Hiromi Nakamura, Takao Kawai

Division of Microbiology, Osaka Institute of Public Health, 1-3-3 Nakamichi, Higashinari-ku, Osaka, Osaka 537-0025, Japan. Electronic address: yonogi@iph.osaka.jp. · Division of Microbiology, Osaka Institute of Public Health, 1-3-3 Nakamichi, Higashinari-ku, Osaka, Osaka 537-0025, Japan.

Key points

From the paper's conclusion
  • We applied our PCR assay to three foodborne disease outbreaks caused by C. perfringens and examined a total of 241 colonies isolated from 80 fecal specimens.

Abstract

Clostridium perfringens is a causative agent of foodborne disease outbreak among humans that produces two enterotoxins known as C. perfringens enterotoxin (CPE) and C. perfringens binary enterotoxin (BEC). To reduce time and labour requirements, we developed a simultaneous detection method comprising a multiplex real-time polymerase chain reaction (PCR) assay for two enterotoxin genes (cpe and becB) and the species-specific alpha-toxin (also known as phospholipase C [PLC]) gene (cpa [also known as plc]). To determine its sensitivity and specificity, we compared our real-time PCR assay with a conventional PCR assay using 75 strains including 24 bacterial species and found that the results of the two assays were in complete agreement for all tested strains. The detection limits were approximately 3.4 CFU per reaction for cpa and cpe in strain NCTC8239 and 1.6 CFU per reaction for cpa and becB in strain OS1, demonstrating that the real-time PCR assay was approximately 10- to 100-fold more sensitive than the conventional PCR assay. Amplification efficiencies confirmed with strains NCTC8239 and OS1 ranged from 95.6% to 100.6%. We applied our PCR assay to three foodborne disease outbreaks caused by C. perfringens and examined a total of 241 colonies isolated from 80 fecal specimens. Subsequently, the results of the assay were concordant with those of the conventional PCR assay (100%). Our real-time PCR assay exhibited high specificity and sensitivity, making it applicable to screening for foodborne disease outbreaks while reducing time and labour requirements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers