Depth-compensated regularization for volumetric inverse electrocardiography.

Jorge Vicente-Puig, Ole Løseth Elvetun, Bjørn Fredrik Nielsen, Judit Chamorro-Servent, Ismael Hernández-Romero

Autonomous University of Barcelona, Department of Mathematics, Bellaterra, Spain. Electronic address: jorge.vicente@corifycare.com. · Norwegian University of Life Sciences, Faculty of Sciences and Technology, Ås, Norway.

Key points

From the paper's conclusion
  • Depth-compensated weighted regularization effectively mitigates epicardial bias in volumetric ECGI, providing a robust framework for non-invasive PVC localization without degrading superficial accuracy. Its applicability is demonstrated on a clinical recording, where the same attenuation of the depth-related bias is observed.

Abstract

OBJECTIVE: Accurate non-invasive localization of Premature Ventricular Contractions (PVCs) is critical for guiding catheter ablation, yet the standard inverse Electrocardiographic Imaging (ECGI) problem suffers from an inherent depth-bias that misprojects deep intramural sources onto the epicardial surface. METHODS: We propose a volumetric estimation of transmembrane potentials by means of a convex optimization functional that integrates depth-compensating weights, derived from the resolution matrix of the forward operator, into both a weighted Lasso (ℓ1) penalty and a weighted Anisotropic Total Variation regularizer, with truncation stabilized by Generalized Cross-Validation. The framework is validated on 625 PVC simulations uniformly distributed throughout a biventricular myocardium, and its applicability is demonstrated on a clinical recording from a public repository comprising 21 catheter-referenced pacing sites. RESULTS: The Weighted Lasso+Weighted TV formulation achieved a median Correlation Coefficient of 0.79 and a median Geodesic Localization Error of 6.98 mm, compared to 0.22 and 35.29 mm, respectively, for the unweighted Lasso baseline. Compared to the unweighted Lasso+TV, the inclusion of depth-compensating weights maintained comparable performance on epicardial sources while reducing the standard deviation of the Geodesic Localization Error from 28.73 mm to 4.92 mm and from 27.48 mm to 4.36 mm for myocardial and endocardial origins, respectively. On the clinical recording, the median Geodesic Localization Error of the unweighted formulation increased from 27.6 mm at non-septal pacing sites to 65.6 mm at septal ones, whereas the depth-compensated formulation remained comparable across both groups, 22.8 and 25.8 mm. CONCLUSION: Depth-compensated weighted regularization effectively mitigates epicardial bias in volumetric ECGI, providing a robust framework for non-invasive PVC localization without degrading superficial accuracy. Its applicability is demonstrated on a clinical recording, where the same attenuation of the depth-related bias is observed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Depth-compensated regularization for volumetric inverse electrocardiography — Science Skim