Visible/near infrared spectroscopy in muscle beef analysis: How device choice and sampling affect prediction accuracy.
A Lopez, J-F Hocquette, B Graulet, I Constant, C Labonne, V Santé-Lhoutellier, S De Smet, A Mouhanna,
INRAE, Université Clermont Auvergne, INRAE, VetAgro Sup, UMR Herbivores, Saint-Genès-Champanelle F-63122, France; Department of Veterinary Medicine and Animal Science (DIVAS), University of Milan, Via dell'Università, 26900 Lodi, Italy. · INRAE, Université Clermont Auvergne, INRAE, VetAgro Sup, UMR Herbivores, Saint-Genès-Champanelle F-63122, France.
Key points
From the paper's conclusion- Overall, Vis/NIR spectroscopy showed strong potential for beef quality assessment, although further optimization is required for portable devices.
Abstract
This study evaluated the performance of two portable spectral devices (visible: Vis; near-infrared: NIR) and one benchtop combined Vis/NIR instrument for predicting beef biochemical traits related to meat quality. A total of 497 muscle samples were collected from 55 fattening farms across five European countries. Reference values were obtained exclusively from pooled samples. For the benchtop device, two sampling strategies were compared: 1) direct scanning of pooled samples (n = 99) used for reference analyses, and 2) scanning individual samples followed by spectral averaging to match pooled references. Partial least squares regression models were developed using several preprocessing methods. For total and heme iron, predictive performance was also evaluated by separately analyzing the visible region of the benchtop device. Results showed that the benchtop Vis/NIR instrument clearly outperformed the portable devices, providing higher prediction accuracies for all traits across the full spectral range. Compared with portable instruments, the benchtop device achieved superior performance for proximate composition (R2 = 0.51-0.85 vs 0.10-0.22), major fatty acids (R2 = 0.50-0.68 vs 0.01-0.31), and total and heme iron (R2 = 0.79-0.93 vs 0.46-0.91). Moreover, scanning individual samples and averaging spectra yielded better prediction models than direct scanning of pooled samples, with good accuracies for moisture, protein, fat content, major saturated and monounsaturated fatty acids, and iron. Conversely, poor prediction (R2 < 0.40) was observed for polyunsaturated fatty acids, TBARS, carnosine, anserine, zinc, selenium and B-group vitamins. Overall, Vis/NIR spectroscopy showed strong potential for beef quality assessment, although further optimization is required for portable devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Discrimination of beef meat according to the level of farming intensification through visible and near infrared spectroscopy data and chemometricsMeat Science · 2026
- Portable near-infrared spectroscopy combined with machine learning for rapid detection of broiler breast myopathies.Poultry science · 2026
- From Benchtop to Handheld Systems: Calibration Transfer for On-Site NIR System Butter Quality Monitoring.Sensors (Basel, Switzerland) · 2026
- Predicting beef palatability using conventional and rapid analytical methods: A random forest approach.Meat science · 2026
- Pork adulteration detection in minced beef powders with varying fat content using near-infrared (NIR) spectroscopy.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Accurate prediction of beef short-rib quality through infrared spectral imaging.Meat science · 2026