Legal medicine (Tokyo, Japan)

How accurate is vitreous potassium for post-mortem interval estimation? A systematic review and meta-analysis of prediction error (mean absolute error).

Eva Montanari, Giovanni Tossetta, Ersi Kalfoğlu, Francesco Paolo Busardò, Angelo Montana

Section of Legal Medicine, Azienda Ospedaliero Universitaria delle Marche, Ancona, Italy. Electronic address: eva.montanari@ospedaliriuniti.marche.it. · Department for the Promotion of Human Science and Quality of Life, San Raffaele Roma University, Italy.

Meta-analysis

Key points

From the paper's conclusion
  • Vitreous potassium should support, not independently determine, PMI estimation.

Abstract

Vitreous potassium has been investigated as a marker of the post-mortem interval (PMI) since the 1960s, yet no prediction equation has demonstrated reproducible accuracy across populations, analytical methods and PMI ranges. This systematic review and meta-analysis quantified their predictive accuracy as mean absolute error (MAE) in hours and examined variation by PMI spectrum and validation design. Searches of PubMed and Scopus identified 582 records. Forty studies met the eligibility criteria; 27 contributed to quantitative synthesis. MAEs reported or calculable from case-level errors (direct) were analysed separately from MAEs reconstructed from aggregate statistics. Twelve direct MAEs (646 cases) yielded a summary estimate of 4.55 h (95% CI 1.46-7.65, I2 = 96.6%), which does not represent the expected error of any individual equation. Sixteen reconstructed estimates (3109 cases) yielded 7.89 h (95% CI 5.28-10.50, I2 = 99.0%). Error was greater in cohorts extending beyond 60 h (10.20 and 11.92 h). Each 10-h increase in evaluated PMI-window width increased MAE by 0.72 h (direct) and 0.73 h (reconstructed), explaining most of the between-study variance. All 28 model-cohort evaluations were at high risk of bias (PROBAST), and none underwent external validation. The accuracy of vitreous potassium for PMI estimation cannot currently be established: it was highly heterogeneous and depended on the population, analytical method and PMI range in which each model was evaluated. Vitreous potassium should support, not independently determine, PMI estimation. Future research should prioritize adequately powered external validation and standardized reporting of prediction error.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers