Evaluation of the laboratory assessment process for A Clinically Oriented Antimicrobial Resistance Surveillance Network (ACORN-LAP) in low-income and middle-income countries: a multicountry, cross-sectional analysis with longitudinal quality monitoring.
ACORN Laboratory Investigators
Key points
From the paper's conclusion- The findings support the use of structured laboratory assessment with ongoing quality monitoring to strengthen AMR surveillance, particularly in non-accredited laboratories. A simple, harmonised global online tool with integrated quality monitoring that assesses against a minimum standard could improve the quality and comparability of AMR surveillance data in low-income and middle-income countries.
Abstract
BACKGROUND: High-quality microbiology laboratory data underpin effective antimicrobial resistance (AMR) surveillance. Laboratory assessments are useful for ensuring the quality of microbiology data used for AMR surveillance, especially in low-income and middle-income countries where accreditation might not be feasible. In this study, we aimed to evaluate the microbiology laboratory assessment and quality monitoring tools developed to assess laboratories participating in A Clinically Oriented Antimicrobial Resistance Surveillance Network 2 (ACORN2). METHODS: We conducted a multicountry observational study of microbiology laboratories participating in the ACORN2 surveillance project, including a baseline cross-sectional laboratory assessment process (ACORN-LAP) with longitudinal quality monitoring and follow-up. Between Sept 21, 2021, to Nov 25, 2024, all laboratories of hospitals identified as ACORN2 sites identified through investigator networks were invited to complete the ACORN-LAP. These laboratories were from nine countries across Asia and Africa. The assessment included an online REDCap-based assessment, and document-based and video call-based reviews by two selected ACORN assessors. The laboratories participated in quarterly quality monitoring processes, including the review of internal quality control (IQC) and external quality assessment (EQA) results. Anonymous feedback was collected, and an in-person feedback session was conducted during the study. The primary evaluation outcome was the findings of the ACORN-LAP, including the number of key and non-key recommendations identified. Secondary evaluation outcomes included quality monitoring performance, laboratory feedback on the ACORN-LAP and quality monitoring processes, and comparison of the ACORN-LAP and quality monitoring processes with existing laboratory assessment tools. FINDINGS: 20 laboratories completed the ACORN-LAP. The median time from initial contact with the laboratory to issuing recommendations was 3 months (IQR 3-4; range 1-8). The assessors identified 144 recommendations (median 6 per laboratory [IQR 3-8·5]; range 2-21), including 46 key and 98 non-key recommendations. Non-accredited laboratories received more recommendations per laboratory than accredited laboratories (median difference 5 [95% CI 1-11]; p=0·0062 and incidence rate ratio (IRR) 2·5 [95% CI 1·56-4·09]; p=0·0002). Non-accredited laboratories also received more key recommendations per laboratory (median difference 2 [95% CI 1-5]; p=0·0030) and IRR 4·75 [95% CI 2·11-11·84]; p=0·0003). 116 quality monitoring forms were completed (median 6 per laboratory [IQR 4-7]; range 2-9). 115 IQC and 59 scored EQA events were reported. Review of such quality monitoring data identified previously undetected IQC failures and led to improved IQC recording in some laboratories. Feedback showed that laboratories considered the assessment process useful although some laboratories found the assessment process labour intensive. INTERPRETATION: The findings support the use of structured laboratory assessment with ongoing quality monitoring to strengthen AMR surveillance, particularly in non-accredited laboratories. A simple, harmonised global online tool with integrated quality monitoring that assesses against a minimum standard could improve the quality and comparability of AMR surveillance data in low-income and middle-income countries. FUNDING: Wellcome Trust.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Laboratory tools from the Fleming Fund antimicrobial resistance surveillance programme.Bulletin of the World Health Organization · 2026
- Laboratory performance of antimicrobial susceptibility testing for GLASS pathogens among participants in the EQuAfrica programme, 2021‒2025PLOS Global Public Health · 2026
- Prospective characterisation of drug-resistant bloodstream infections in Africa and Asia (ACORN2): a surveillance network assessmentThe Lancet Microbe · 2025
- Generating Actionable Data From Antimicrobial Resistance Surveillance: Insights From the Fleming Fund's International Experience.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026
- Implementing AMR surveillance at a tertiary hospital in a low-income country: results from the Surveillance Partnership to Improve Data for Action on AMR (SPIDAAR) in Malawi.Antimicrobial resistance and infection control · 2026
- Antimicrobial Stewardship, Laboratory Surveillance, and Quality Management in Africa: A Narrative Review of Challenges and Opportunities for Integrated AMR Control.Health science reports · 2026