Laboratory investigation; a journal of technical methods and pathology

Field-of-View Impact on Multiclass Tissue Segmentation: Systematic Analysis Across Structure Sizes and Multiple Cancer Types.

Donghyeok Jo, Jongwon Lee, Suk-Young Lee, Baek-Hui Kim, Hakseung Kim, Byung Chul Yoon, Dong-Joo Kim

Department of Brain and Cognitive Engineering, Korea University, Seoul, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, South Korea. · Department of Brain and Cognitive Engineering, Korea University, Seoul, South Korea; Department of Pathology, Korea University College of Medicine, Seoul, South Korea.

Key points

From the paper's conclusion
  • Field-of-view fundamentally determines detection capability for size-specific tissue structures. Performance plateaued between 384×384 and 512×512 pixels, and the 384×384 field-of-view offers a favorable balance between performance and computational efficiency. The approach generalized to other cancer types without fine-tuning.

Abstract

PURPOSE: Patch-based deep learning in digital pathology requires selecting a field-of-view size, a choice usually made without systematic justification. Tumor-infiltrating lymphocytes, measuring 5-10 μm, depend on the surrounding tissue context for identification. We aimed to determine how field-of-view size affects multiclass segmentation of tissue structures of different sizes at a fixed resolution and to identify a size that balances accuracy and computational cost. MATERIALS AND METHODS: An EfficientNet-B3 U-Net was trained on the PanopTILs breast cancer dataset (153 whole-slide images) across five field-of-view sizes (224×224 to 512×512 pixels; 112-256 μm) at 0.5 μm/pixel. Four tissue classes were segmented and evaluated using 5-fold cross-validation with patient-level splits. Resized-patch controls and a 0.25 μm/pixel series separated field-of-view effects from resolution effects. The trained model was then applied to bladder and colon cancer tissues, and its tumor-infiltrating lymphocyte detection was compared with pathologist review. RESULTS: Detection sensitivity showed a strong inverse correlation with structure size (Pearson r = -0.98, p = 0.016). From 224×224 to 512×512 pixels, tumor-infiltrating lymphocyte segmentation improved by 46.6% (Dice score: 0.309 to 0.453, p = 0.0003) and stromal segmentation by 24.7% (p = 0.0001), while large structures remained stable (+0.4%). Overall Dice score plateaued between 384×384 and 512×512 pixels. At a fixed 224×224-pixel input, enlarging the tissue area by downsampling reduced the Dice score. The 384×384 field-of-view achieved 94.5% of maximum performance with 6.07 billion multiply-accumulate operations per image, compared with 10.79 billion for 512×512. Cross-cancer validation yielded 92% accuracy in bladder and 88% in colon cancer (Cohen's kappa = 0.85 and 0.94). CONCLUSIONS: Field-of-view fundamentally determines detection capability for size-specific tissue structures. Performance plateaued between 384×384 and 512×512 pixels, and the 384×384 field-of-view offers a favorable balance between performance and computational efficiency. The approach generalized to other cancer types without fine-tuning.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers