Preoperative alignment-dependent coronal laxity persists after mechanically aligned total knee arthroplasty but not kinematically aligned total knee arthroplasty: a longitudinal stress radiographic study.
Ryota Fujii, Tsuneari Takahashi, Taisei Goto
Department of Orthopedic Surgery, Seirei Fuji Hospital, Fuji, Shizuoka, Japan. · Department of Orthopaedics, School of Medicine, Jichi Medical University, Shimotsuke, Japan. Electronic address: tsuneari9@jichi.ac.jp.
Key points
From the paper's conclusion- Preoperative alignment was associated with postoperative stress varus angles throughout the first postoperative year after MA-TKA, whereas no statistically significant association was detected after KA-TKA. Between-group differences in correlation coefficients were statistically significant at 2 weeks, 3 months, and 6 months, but not at 1 year. However, the independent contribution of alignment technique could not be determined because of confounding by surgeon, implant design, and intraoperative balancing targets.
Abstract
BACKGROUND: In mechanically aligned total knee arthroplasty (MA-TKA), postoperative coronal laxity has been reported to correlate with the severity of preoperative varus deformity. Whether kinematically aligned TKA (KA-TKA) modifies this relationship remains unknown. This study aimed to compare postoperative coronal laxity between MA-TKA and KA-TKA using longitudinal stress radiography, and to determine whether the association between the preoperative hip-knee-ankle angle (HKA) and postoperative coronal laxity differs between the two alignment strategies. METHODS: Patients who underwent primary TKA for osteoarthritis were divided into an MA-TKA group, in which a bi-cruciate stabilized implant was used, and a KA-TKA group, in which a medial stabilized implant was used. Propensity score matching based on age, sex, body mass index, and preoperative HKA yielded 31 knees per group. Varus and valgus stress radiographs were obtained in full extension using a Telos device at 2 weeks, 3 months, 6 months, and 1 year postoperatively. Spearman's rank correlation coefficients (ρ) between the preoperative HKA and postoperative stress angles were calculated separately for each group, and radiographic alignment parameters were compared between groups. RESULTS: In the MA-TKA group, significant negative correlations were observed between the preoperative HKA and postoperative stress varus angles at all time points (ρ = -0.655 to -0.395, all p < 0.05), whereas no significant correlations were identified in the KA-TKA group (all p > 0.05). The between-group differences in correlation coefficients were significant at 2 weeks, 3 months, and 6 months (Fisher's r-to-z transformation, all p < 0.05), but not at 1 year (p = 0.079). Stress varus angles were significantly larger in the MA-TKA group throughout follow-up (5.4 ± 1.8° versus 2.4 ± 1.0° at 1 year, p < 0.001). In contrast, overall limb alignment and the magnitude of joint line convergence angle (JLCA) correction were comparable between groups: the postoperative HKA did not differ (-2.7 ± 2.3° versus -2.4 ± 2.7°, p = 0.613), and the magnitude of JLCA correction did not differ significantly (3.7 ± 2.4° versus 4.4 ± 2.8°, p = 0.382). Within the MA-TKA group, partial correlation analysis showed that the preoperative HKA and the postoperative mechanical lateral distal femoral angle were each associated with the stress varus angle at 1 year independently of the other (r = -0.399 and r = -0.403, both p < 0.05). CONCLUSION: Preoperative alignment was associated with postoperative stress varus angles throughout the first postoperative year after MA-TKA, whereas no statistically significant association was detected after KA-TKA. Between-group differences in correlation coefficients were statistically significant at 2 weeks, 3 months, and 6 months, but not at 1 year. However, the independent contribution of alignment technique could not be determined because of confounding by surgeon, implant design, and intraoperative balancing targets. LEVEL OF EVIDENCE: Level III, retrospective comparative study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Kinematic alignment reduces tibial internal rotation and maintains a larger retropatellar contact area than mechanical alignment in early flexion in valgus knees.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- Unrestricted kinematic alignment in varus total knee arthroplasty outperforms mechanical alignment in CPAK I phenotype, but yields comparable outcomes in CPAK IV: A retrospective analysis from the FP‐UCBM Knee Study GroupKnee Surgery Sports Traumatology Arthroscopy · 2025
- Tibiofemoral and patellofemoral kinematics after kinematic versus mechanical alignment in varus TKA-a dynamic knee rig study.Archives of orthopaedic and trauma surgery · 2026
- Mechanical Versus Kinematic Alignment in Total Knee Arthroplasty: Relationship Between Postoperative Alignment and Short-Term Functional Outcomes.Diagnostics (Basel, Switzerland) · 2026
- Influence of total knee arthroplasty on coronal plane phenotypes and associated clinical outcomes: a CPAK-based comparison between mechanical and functional alignment.Journal of robotic surgery · 2026
- Kinematic alignment versus mechanical alignment in total knee arthroplasty: a systematic review and meta-analysis of medium to long-term outcomes.Musculoskeletal surgery · 2026