Journal of voice : official journal of the Voice Foundation

Voice as a Candidate Digital Biomarker: Preliminary Comparison of Classical Acoustic Analysis and Self-Supervised Learning Models.

Antonino Maniaci, Moreno La Quatra, Maria Stella Di Modica, Andy Bertolin, Maria Rosaria Barillari, Marco Lionello, Mario Lentini, Jérôme R Lechien,

Department of Medicine and Surgery, University of Enna "Kore," Enna, Italy; Unit of Otorhinolaryngology, ASP Ragusa ("Maggiore-Baglieri" Hospital, Modica), Ragusa, Italy; Department of Otolaryngology-Head and Neck Surgery, Foch Hospital, Université Paris-Saclay, Suresnes, France; Department of Otolaryngology-Head and Neck Surgery, EpiCURA Hospital, University of Mons, Mons, Belgium. Electronic address: antonino.maniaci@unikore.it. · Department of Engineering and Architecture, University of Enna "Kore," Enna, Italy.

Observational · n=40

Key points

From the paper's conclusion
  • End-to-end fine-tuned SSL models achieved the highest point estimates among the pipelines compared in this pilot cohort, but the small test set and marked age/sex imbalance between groups mean these findings are preliminary and require confirmation in larger, independent cohorts.

Abstract

OBJECTIVES/HYPOTHESIS: To compare, in a real-world multicentre clinical cohort, three analytic approaches for distinguishing healthy from pathological voices: classical Praat-derived acoustic analysis with conventional machine-learning classifiers; self-supervised learning (SSL) models used as frozen feature extractors; and SSL models fully adapted via end-to-end fine-tuning. STUDY DESIGN: Prospective, multicentre, controlled observational study conducted at three Italian clinical centers, reported in accordance with STROBE guidelines. METHODS: 200 Italian-speaking adults (100 healthy, 100 with confirmed laryngeal pathology) provided voice recordings of sustained vowel phonation, diadochokinetic repetition, and sentence reading. Three analytic pipelines were compared on a speaker-disjoint held-out test set (n = 40): (1) Praat-derived acoustic features with machine-learning classifiers; (2) frozen SSL embeddings (wav2vec2, HuBERT, voc2vec); and (3) the same SSL backbones fully fine-tuned end-to-end (E2E). RESULTS: Patient-level accuracy ranged from 75.0% to 95.0% across 14 pipelines. The best-performing system was an E2E fine-tuned voc2vec/HuBERT model (sensitivity, specificity, PPV, NPV, and accuracy all 95.0%; AUC 0.992). The best frozen-SSL configuration (HuBERT-base, LibriSpeech) reached 90.0% accuracy (AUC 0.980), and the best classical pipeline (Praat + SVM) reached 85.0% accuracy (AUC 0.927), with high sensitivity but comparatively low specificity. CONCLUSIONS: End-to-end fine-tuned SSL models achieved the highest point estimates among the pipelines compared in this pilot cohort, but the small test set and marked age/sex imbalance between groups mean these findings are preliminary and require confirmation in larger, independent cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers