Journal of vascular and interventional radiology : JVIR

Tract Sealing in Percutaneous Liver Biopsy: A Systematic Review of Comparative and Single-Arm Studies.

Eimear T Kyle, Kevin J Sweeney, Niall J O'Sullivan, Hugo C Temperley, Benjamin M Mac Curtain, Kevin P Sheahan

School of Medicine, Trinity College Dublin, Dublin, Ireland; Trinity St. James's Cancer Institute, St. James's Hospital, Dublin, Ireland; Department of Radiology, Sir Charles Gairdner Hospital, Nedlands, Western Australia, Australia. Electronic address: kylee@tcd.ie. · Department of Radiology, Sir Charles Gairdner Hospital, Nedlands, Western Australia, Australia.

Meta-analysis

Key points

From the paper's conclusion
  • Tract sealing was associated with fewer major bleeding-related adverse events but not fewer events overall. The evidence supports selective use in patients with identifiable bleeding risk but does not establish benefit in unselected low-risk patients.

Abstract

PURPOSE: To compare bleeding-related adverse events after percutaneous liver biopsy with and without tract sealing, separating clinical outcomes from randomized evidence on a surrogate endpoint. MATERIALS AND METHODS: Systematic review following PRISMA 2020 guidelines. Five databases were searched (2000 to August 2026) for percutaneous liver biopsy with tract sealing by any agent or energy. Adverse events were graded on the Society of Interventional Radiology scale as mild (grade 1) or moderate to fatal (grades 2 to 5). Comparative data were pooled using random-effects models, with the Peto method for major bleeding. Risk of bias was assessed with RoB 2 and ROBINS-I. RESULTS: Twenty-two studies reporting 4,560 liver biopsy procedures were included. Two retrospective studies compared sealing with no sealing on clinically defined outcomes. Overall bleeding-related adverse events did not differ (OR 0.52; 95% CI 0.13-2.17; P = .370), whereas major bleeding was less frequent with sealing (Peto OR 0.09; 95% CI 0.02-0.42; P = .002; absolute risk difference 3.3%). Two randomized trials favored sealing on a Doppler surrogate but not on clinically significant bleeding. Major bleeding in single-arm cohorts ranged from 0% to 2.2%. Three studies comparing plugged percutaneous with transjugular biopsy allocated patients with worse coagulation indices to the transjugular arm. CONCLUSION: Tract sealing was associated with fewer major bleeding-related adverse events but not fewer events overall. The evidence supports selective use in patients with identifiable bleeding risk but does not establish benefit in unselected low-risk patients.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers