Adaptation and Initial Psychometric Validation of the Clinician Satisfaction with Sedation Instrument (CSSI) for Interventional Radiology.
Amy R Deipolyi, Michael V Korona, Ashraf Ahmad, Adam Belcher
West Virginia School of Medicine, Charleston Division, 3200 MacCorkle Ave SE, Charleston, WV, 25304; Interventional Radiology, Department of Surgery, Charleston Area Medical Center, 3200 MacCorkle Ave SE, Charleston, WV, 25304. Electronic address: amy.deipolyi@camc.org. · Interventional Radiology, Department of Surgery, Charleston Area Medical Center, 3200 MacCorkle Ave SE, Charleston, WV, 25304.
Key points
From the paper's conclusion- The adapted 13-item CSSI demonstrated excellent internal consistency and initial evidence of reliability and validity for measuring clinician satisfaction with procedural sedation in interventional radiology. The instrument shows potential as a standardized clinician-reported outcome measure for future comparative sedation studies.
Abstract
PURPOSE: To adapt and psychometrically validate the Clinician Satisfaction with Sedation Instrument (CSSI) for use in interventional radiology (IR), including assessment of reliability and validity. MATERIALS AND METHODS: In this prospective observational study, clinician responses were collected following adult IR procedures performed with IR-administered procedural sedation. The original 21-item CSSI was adapted for IR using face validity assessment and pilot testing, resulting in a 13-item instrument. Internal consistency, exploratory factor analysis, inter-rater reliability, criterion validity, construct validity, and convergent validity were evaluated. A secondary cohort assessed physician-physician agreement. RESULTS: One hundred one procedures generated 272 completed surveys from 12 clinicians (10 nurses, 2 physicians). The adapted CSSI demonstrated excellent internal consistency (Cronbach α = 0.968) and a unidimensional factor structure accounting for 73.1% of variance. Inter-rater reliability was moderate between physicians and nurses (ICC = 0.547) and good among nurses (ICC = 0.763). Physician-physician reliability demonstrated good consistency (ICC = 0.688). CSSI scores increased with patient vocalization severity (P < .001), patient movement (P = .041), sedation-related complications (P < .001), multiple procedures (P < .001), and differed across procedure types (P = .030) and sedation regimens (P < .001). CSSI scores also correlated with deepest procedural sedation level (Spearman r = 0.491, P = .028). CONCLUSION: The adapted 13-item CSSI demonstrated excellent internal consistency and initial evidence of reliability and validity for measuring clinician satisfaction with procedural sedation in interventional radiology. The instrument shows potential as a standardized clinician-reported outcome measure for future comparative sedation studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Validation of the Chinese Physicians' Reactions to Uncertainty Scale for Endoscopy: A Mixed-Methods Approach.Canadian journal of gastroenterology & hepatology · 2026
- Content validity of the Scale for Assessing the Risk of Phlebitis in Hospitalized Adults.Revista brasileira de enfermagem · 2026
- Validation and Psychometric Properties of the Vietnamese Versions of the Test of Adherence to Inhalers (TAI) and Inhaler Medication Adherence Scale (IMAS) in Patients with Chronic Obstructive Pulmonary Disease.Tuberculosis and respiratory diseases · 2026
- Validity and Reliability of the Turkish IPREA-18: A Psychometric Study in Intensive Care Unit Patients.Journal of nursing measurement · 2026
- Psychometric validation of the informed consent assessment scale using item response theory and factor analysisFrontiers in Medicine · 2026
- Development and psychometric properties of a questionnaire to evaluate the professional behavior of medical residents.PloS one · 2026