Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology

Comparing traditional, strain and ellipsoid model indices of right ventricular function with real-time three-dimensional echocardiographic ejection fraction in dogs.

B E Tagg, R Ciardullo, S B Mintz, R Pariaut, W Hsue

Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, 930 Campus Road, Ithaca, NY, 14853, USA. · Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, 930 Campus Road, Ithaca, NY, 14853, USA. Electronic address: wh446@cornell.edu.

Key points

From the paper's conclusion
  • Although AEM-EF and LEM-EF can estimate EF from two-dimensional images, they show poor agreement with RT3D-EF and do not outperform FAC. Additionally, neither TAPSEn nor S'n correlated with RT3D-EF, highlighting the need for further validation of these indices against robust reference standards.

Abstract

INTRODUCTION/OBJECTIVES: Ejection fraction (EF) provides a global assessment of right ventricular (RV) function but is challenging to calculate because of complex geometry. The ellipsoid model enables estimation of EF from two-dimensional echocardiography using area-based or linear-based formulas (AEM-EF and LEM-EF). The objective of the present study was to compare AEM-EF, LEM-EF and other indices of RV function against real-time three-dimensional echocardiographic EF (RT3D-EF). ANIMALS, MATERIALS AND METHODS: Seventy-three dogs (23 healthy, 50 with right-sided heart disease) were prospectively imaged. Measurements included basal, mid-cavity, longitudinal and outflow tract fractional shortening; body weight-normalized tricuspid annular plane systolic excursion (TAPSEn); body weight-normalized tissue Doppler-derived tricuspid annular peak systolic myocardial velocity (S'n); fractional area change (FAC); free wall strain and global longitudinal strain; AEM-EF and LEM-EF; and RT3D-EF. RESULTS: All indices except TAPSEn and S'n correlated with RT3D-EF. Systematic biases for AEM-EF and LEM-EF relative to RT3D-EF were minimal (mean difference [95% confidence interval]: 2.8% [0.4-5.2%] and -1.0% [-3.5 to 1.5%]), although agreements were poor (rc [95% confidence interval] = 0.627 [0.476-0.742] and 0.588 [0.420-0.718]). The FAC and free wall strain were the strongest independent predictors of RT3D-EF in multivariate regression (R2 adjusted = 0.519). STUDY LIMITATIONS: The main limitation of the present study is the absence of a true reference standard for RV function. CONCLUSIONS: Although AEM-EF and LEM-EF can estimate EF from two-dimensional images, they show poor agreement with RT3D-EF and do not outperform FAC. Additionally, neither TAPSEn nor S'n correlated with RT3D-EF, highlighting the need for further validation of these indices against robust reference standards.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparing traditional, strain and ellipsoid model indices of right ventricular function with real-time three-dimensional echocardiographic ejection fraction in dogs — Science Skim