Responsiveness, Test-Retest Reliability, and Minimal Important Change of QLU-C10D, PROPr, and EQ-5D-5L in Cancer Patients.
Antje Förster, Alexander Obbarius, Felix Fischer, Annika Döhmen, Milan Kock, Kathrin Rieger, Ulrich Keilholz, Matthias Rose,
Department of Psychosomatic Medicine, Center for Internal Medicine and Dermatology, Charité - University Medicine, Berlin, Germany. Electronic address: antje.foerster@charite.de. · Department of Psychosomatic Medicine, Center for Internal Medicine and Dermatology, Charité - University Medicine, Berlin, Germany; Dornsife Center for Self-report Science, University of Southern California, Los Angeles, CA, USA.
Key points
From the paper's conclusion- The psychometric performance of the QLU-C10D, the PROPr, and EQ-5D-5L was similar. We could not find evidence for preferring one over the other for QALY estimation in cost-effectiveness analyses. Poor discriminatory power between changed and unchanged patients is a major concern.
Abstract
OBJECTIVES: Cost-effectiveness analyses typically rely on health state utility (HSU) scores for the calculation of quality-adjusted life years (QALY). As such analyses influence access to treatment, the psychometric properties of the HSU instruments are crucial. Beyond the established EQ-5D-5L, for the relatively new QLU-C10D and PROPr, there is limited empirical evidence on their psychometric properties. Thus, this study aimed to compare their responsiveness, test-retest reliability, and minimal important change. METHODS: EQ-5D-5L, QLU-C10D, and PROPr were collected at five timepoints in an observational sample of 390 outpatient cancer patients. Change groups were determined by both retrospective and prospective anchors. Responsiveness was measured by standardized response mean (SRM), standardized effect size (SES), and detection of change by area under the curve (AUC). Test-retest reliability was measured by intraclass correlation coefficients (ICC). We estimated minimal important change (MIC) with a logistic regression analysis. RESULTS: SRM and SES were mostly small to moderate for all instruments. AUC was poor in all instruments, but significantly higher for the QLU-C10D (0.68-0.69) and PROPr (0.68) than EQ-5D-5L (0.62) in prospective change. ICC was significantly higher for PROPr (0.86) than EQ-5D-5L (0.77) in retrospective change. MIC from T0-T1 was similar for all instruments: 0.03-0.05 for improvement and -0.06 to -0.01 for deterioration. CONCLUSIONS: The psychometric performance of the QLU-C10D, the PROPr, and EQ-5D-5L was similar. We could not find evidence for preferring one over the other for QALY estimation in cost-effectiveness analyses. Poor discriminatory power between changed and unchanged patients is a major concern.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VIP: validation of Italian patient-reported outcomes version of the common terminology criteria for adverse events (PRO-CTCAE), a FICOG prospective multicentre study - results of the colorectal cancer (CRC) cohort.BMJ oncology · 2026
- Cross-cultural adaptation and psychometric assessment of the Chinese version of the University of Wisconsin Running Injury and Recovery Index in runners.BMC musculoskeletal disorders · 2026
- Meaningful differences and changes for five Patient‐Reported Outcomes Measurement Information System domains in a large cohort of patients with cancerCancer · 2025
- Minimal clinically important differences and the illusion of precision.BMJ supportive & palliative care · 2026
- Real-world evaluation of the christie symptom inventory-lung cancer (CSI-lung) electronic patient-reported outcome measure: validity, reliability, responsiveness, and patient experiences.Lung cancer (Amsterdam, Netherlands) · 2026
- Within-person variability and the minimal important difference of the EQ-VAS in adults with post-COVID-19 condition: a secondary analysis of data from a single-centre randomised controlled trial.BMJ open · 2026