Curvature characteristics of the head and neck and potential anatomical vulnerability to medical device-related pressure injuries.
Eun-Seon Yang, In Cheol Jeong
Cerebrovascular Disease Research Center, Hallym University, Chuncheon, 24252, Republic of Korea. · Cerebrovascular Disease Research Center, Hallym University, Chuncheon, 24252, Republic of Korea; Department of Artificial Intelligence Convergence, Hallym University, Chuncheon, 24252, Republic of Korea; Department of Neurology, College of Medicine, Hallym University, Chuncheon, 24252, Republic of Korea; Department of Population Health Science and Policy, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA. Electronic address: incheol.jeong@hallym.ac.kr.
Key points
From the paper's conclusion- Our findings suggest that curvature characteristics may differ by sex and measurement location and potentially influence head and neck MDRPI vulnerability. As these values are obtained from healthy adults, further validation in patients requiring prolonged use of head and neck medical devices is needed before they can inform nursing practice.
Abstract
AIM: This study aimed to quantify local curvature at key head and neck sites using three-dimensional (3D) scan data and establish sex- and site-specific radius of curvature (ROC) values as reference data on potential anatomical vulnerability to medical device-related pressure injuries (MDRPIs). MATERIALS AND METHODS: This cross-sectional study used 3D facial and neck scan data from 100 Korean adults (men = 50, women = 50) provided by AI-Hub. Seven bilateral measurement points were defined using standardized section planes, interplanar spacing, and a fixed 25-mm chord length. Intra-rater test-retest reliability was evaluated in 20 randomly selected participants after 3 months using intraclass correlation coefficients (ICCs) and repeatability metrics. RESULTS: Men showed lower mean ROC values (86-105 mm) and greater variability, with a nominal left-right difference only at upper-face point A (p = 0.038, exploratory), while women demonstrated more consistent ROC values (189-192 mm). Intra-rater test-retest analysis indicated excellent repeatability (ICCs: 0.985-0.998). CONCLUSION: Our findings suggest that curvature characteristics may differ by sex and measurement location and potentially influence head and neck MDRPI vulnerability. As these values are obtained from healthy adults, further validation in patients requiring prolonged use of head and neck medical devices is needed before they can inform nursing practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exploratory Agreement of 3D Body Surface Analysis with Expert Manual Assessment of Pelvic Malalignment in Patients with Non-Acute Low Back Pain: A Prospective Pilot Study with Linked Post-Hoc Analyses.Diagnostics (Basel, Switzerland) · 2026
- Nurses' knowledge and practices regarding medical device-related pressure injuries: a cross-sectional study.Journal of wound care · 2026
- Normative Distal Radius Radiological Measurements: The Influence of Age, Gender, and Menopause.Clinical medicine insights. Arthritis and musculoskeletal disorders · 2026
- Demographic variation of styloid process morphology in panoramic radiographyBMC Oral Health · 2026
- Morphometric Analysis of Redundant Sigmoid Colon in Patients with Difficult Colonoscopy: A Gender-Based StudyMuş Alparslan Üniversitesi Sağlık Bilimleri Dergisi · 2026