Response to methodological concerns regarding the assessment of the OMIUS™ cooling headband during submaximal running and a 5-km time trial in hot/humid conditions.
Antoine Jolicoeur Desroches, Eric D B Goulet
Faculty of Physical Activity Sciences, Université de Sherbrooke, Sherbrooke, Québec, Canada; Performance, Hydration and Thermoregulation (PHT) Laboratory, Université de Sherbrooke, Sherbrooke, Québec, Canada. · Faculty of Physical Activity Sciences, Université de Sherbrooke, Sherbrooke, Québec, Canada; Performance, Hydration and Thermoregulation (PHT) Laboratory, Université de Sherbrooke, Sherbrooke, Québec, Canada. Electronic address: Eric.Goulet@usherbrooke.ca.
Key points
From the paper's conclusion- Overall, the OH produced statistically significant local forehead cooling and improved forehead thermal comfort during the fixed-intensity exercise period, but no statistically significant improvement in 5-km TT performance was demonstrated, while a practical worthwhile effect cannot be excluded.
Abstract
This response addresses the seven methodological concerns raised regarding the study by Jolicoeur Desroches et al. (2024). We acknowledge that the relatively small sample and greater-than-anticipated variability in 5-km time-trial (TT) performance limited the precision of the performance-effect estimate. However, several interpretations advanced in the Forum article are not supported by the evidence. The assertion that the OMIUS™ headband (OH) operated at only 60% of its designed cooling capacity relies on an unverified saturation requirement and does not account for water-application frequency or moisture supplied by sweating. The data provide no evidence of progressive loss of local cooling by the OH during the TT. Pre-cooling the placebo headband to 4°C produced an initial cooling effect, but it was short-lived and forehead temperature was lower with the OH during the fixed-intensity exercise period. Adjustment for baseline rectal temperature did not alter the performance conclusion. Although not clearly indicated in the initial study, fan settings were standardized within participants. Aural canal temperature was excluded because of measurement-validity concerns. The placebo condition was intended to minimize expectancy-related placebo and nocebo effects. Sample size was prospectively and correctly determined using reproducibility data and an a priori practically meaningful effect. Complementary second-generation p-value analysis indicates that both practically trivial and worthwhile effects remain compatible with the data. Overall, the OH produced statistically significant local forehead cooling and improved forehead thermal comfort during the fixed-intensity exercise period, but no statistically significant improvement in 5-km TT performance was demonstrated, while a practical worthwhile effect cannot be excluded.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of pre-cooling by cold-water immersion on continuous sweat conductivity kinetics during submaximal exercise in the heat.Journal of thermal biology · 2026
- Cooling and exercise performance in adult men at ≥30°C: a task-stratified systematic review and three-level meta-analysis.Journal of thermal biology · 2026
- Efficacy of a Meta-Analysis-Recommended Immersion Protocol vs. Field-Practical Cold-Water Immersion Protocol for Performance Recovery: A Randomized Crossover Trial.Journal of strength and conditioning research · 2026
- The Effectiveness of Cooling Vests in Reducing Physiological Strains of Occupational Heat Stress Among Construction Workers.Journal of occupational and environmental medicine · 2026
- Partial Immersion Using Body Bags for Exertional Hyperthermia: A Randomized Crossover Study.The western journal of emergency medicine · 2026
- Respiratory and Aerobic Responses Associated with Improved Endurance Exercise Performance Following Cold Drink Pre-Cooling in the Heat.Life (Basel, Switzerland) · 2026