Immediate effect of hot and cold lumbar douche on gastric myoelectrical activity in healthy individuals: A randomized trial.
Shobhitha Tantry B, Sujatha K J, Prashanth Shetty
Department of Natural Therapeutics, SDM College of Naturopathy and Yogic Sciences, Ujire, Karnataka, India. Electronic address: shobhithatantry@gmail.com. · Department of Natural Therapeutics, SDM College of Naturopathy and Yogic Sciences, Ujire, Karnataka, India. Electronic address: drsujathadinesh2@gmail.com.
Key points
From the paper's conclusion- A brief thermal stimulus over the thoracolumbar region was followed by a small, consistent fall in bradygastric-band frequency with both hot and cold water, independent of signal amplitude. The rise in EGG power after hot application is confounded by possible electrode-skin contact changes. Neither intervention displaced the normogastric rhythm. These findings are hypothesis-generating and do not establish a therapeutic effect.
Abstract
BACKGROUND: Gastric slow-wave dysrhythmias are associated with functional dyspepsia, gastroparesis and constipation. Lumbar douche, a traditional hydrotherapy thought to act on abdominal and pelvic organs by reflex, has not been tested using electrogastrography. OBJECTIVE: To assess the immediate effect of cold and hot lumbar douche on cutaneous electrogastrographic (EGG) measures in healthy adults. METHODS: In this randomized, parallel-group trial, 78 healthy young adults (n = 39 per group) received hot (HLD; 40-52°C) or cold (CLD; 13-21°C) lumbar douche for 30 s. EGG was recorded before and after the intervention, and fifteen spectral parameters were derived from a visually selected 15-min segment per recording. Post hoc analyses tested whether power changes reflected uniform changes in recording gain. RESULTS: Mean bradygastric frequency fell in both arms (HLD 0.0411 to 0.0371 Hz, p < 0.001; CLD 0.0371 to 0.0341 Hz, p = 0.010), without between-arm difference (p = 0.37). After hot douche, power rose in all three bands (1.73- to 2.39-fold), but uniformly: the distribution across bands was unchanged (all p ≥ 0.45) and a gain-independent power ratio did not change (p = 0.070). This cannot be separated from altered electrode-skin contact. CONCLUSION: A brief thermal stimulus over the thoracolumbar region was followed by a small, consistent fall in bradygastric-band frequency with both hot and cold water, independent of signal amplitude. The rise in EGG power after hot application is confounded by possible electrode-skin contact changes. Neither intervention displaced the normogastric rhythm. These findings are hypothesis-generating and do not establish a therapeutic effect. TRIAL REGISTRATION: Clinical Trial Registry of India, CTRI/2025/04/084250.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sedatives reduce human gastric slow-wave amplitude, assessed by a multicenter study of endoscopic gastric mappingmedRxiv · 2026
- The assessment of gastric myoelectrical activity between different stomach regions based on three-channel electrogastrogram signals: a pilot studyFrontiers in Analytical Science · 2026
- Optimizing non-invasive assessment of gastric activity: a fully automated channel-wise pipeline for multi-electrode electrogastrographybioRxiv · 2026
- Effects of Needleless Transcutaneous Electrical Acustimulation on Gastrointestinal Function Recovery After Multi-Level Lumbar Surgery: A Randomized Clinical Trial.Journal of neurogastroenterology and motility · 2026
- Endoscopic gastric pacing: A minimally invasive approach for slow wave entrainment in rhythmic and dysrhythmic states.American journal of physiology. Gastrointestinal and liver physiology · 2026
- LIBPhys-EGG: An open-access multichannel electrogastrography and accelerometry dataset for reproducible research in gastrointestinal electrophysiology.Computer methods and programs in biomedicine · 2026