Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty.
Maxime Antoni, Laurent Obert, Alexandre Quemener, Audrey Manceron, Eloïse Duprot, Claire Bastard, Geoffroy Nourissat
Shoulder and Elbow Surgery Unit, ELSAN - Clinique de l'Orangerie, Strasbourg, France. · Department of Orthopedic Surgery, CHU de Besançon, Besançon, France.
Key points
From the paper's conclusion- Overall sensitivity differed significantly according to radiographic view. RN demonstrated the highest sensitivity (90.7%), followed by RE (54.0%) and RI (29.0%) (P < .001). Specificity was high across all views: 98.3% for RN, 98.3% for RI, and 96.7% for RE. Sensitivity increased with displacement magnitude, but reliable detection was mainly achieved for displacements greater than approximately 5 mm. Interobserver reliability was highest for RN (κ = 0.69; intraclass correlation coefficient [ICC] = 0.70), compared with RE (κ = 0.55; ICC = 0.56) and RI (κ = 0.57; ICC = 0.58). Intraobserver reliability was high, with mean weighted kappa and ICC values of 0.80. Senior observers showed higher overall sensitivity than junior observers (61.6% vs. 54.2%), although view ranking remained unchanged.
Abstract
HYPOTHESIS AND/OR BACKGROUND: Stemless humeral implants rely exclusively on metaphyseal fixation, making post-operative detection of humeral component migration important after stemless reverse shoulder arthroplasty. However, migration assessment on standard radiographs may be influenced by humeral rotation, particularly in the absence of a stem serving as a longitudinal radiographic landmark. The primary objective was to compare the sensitivity of 3 radiographic views, true anteroposterior in neutral rotation (RN), external rotation (RE), and internal rotation (RI), for detecting humeral component migration after stemless shoulder arthroplasty. Secondary objectives were to assess specificity, observer reliability, the influence of experience, and the minimal reliably detected displacement. METHODS: An experimental radiographic study was performed using synthetic humeri implanted with a stemless humeral component. Controlled varus migration was sequentially created at the calcar level to predefined depths of 1, 3, 5, 7, and 10 mm. For each displacement condition, fluoroscopic images were obtained using RN, RE, and RI views. Ninety images were anonymized and presented in fully randomized order to 6 blinded observers, including 3 junior and 3 senior shoulder surgeons. Observers performed a binary assessment of migration presence compared with reference images. The evaluation was repeated after 1 month, resulting in 1,080 individual assessments. Sensitivity, specificity, interobserver and intraobserver reliability, and subgroup analyses according to observer experience were performed. RESULTS: Overall sensitivity differed significantly according to radiographic view. RN demonstrated the highest sensitivity (90.7%), followed by RE (54.0%) and RI (29.0%) (P < .001). Specificity was high across all views: 98.3% for RN, 98.3% for RI, and 96.7% for RE. Sensitivity increased with displacement magnitude, but reliable detection was mainly achieved for displacements greater than approximately 5 mm. Interobserver reliability was highest for RN (κ = 0.69; intraclass correlation coefficient [ICC] = 0.70), compared with RE (κ = 0.55; ICC = 0.56) and RI (κ = 0.57; ICC = 0.58). Intraobserver reliability was high, with mean weighted kappa and ICC values of 0.80. Senior observers showed higher overall sensitivity than junior observers (61.6% vs. 54.2%), although view ranking remained unchanged. DISCUSSION AND/OR CONCLUSION: Radiographic detection of humeral component migration after stemless shoulder arthroplasty is highly dependent on projection and has limited reliability for small displacements. A standardized true anteroposterior view in RN is essential for accurate post-operative assessment, whereas rotational views markedly reduce sensitivity and may contribute to underdiagnosis or overdiagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early radiographic findings are not associated with instability for reverse total shoulder arthroplasty with the Perform metaphyseal-fixated humeral stemJournal of Shoulder and Elbow Arthroplasty · 2026
- Migration patterns of the humeral component of the stemless Simpliciti Shoulder System in stemless anatomic total shoulder arthroplasty A radiostereometric and clinical study with 60-month follow-up.Journal of shoulder and elbow surgery · 2026
- Standard-length stems require lower distal filling ratios than short stems to achieve neutral alignment in reverse total shoulder arthroplasty.JSES international · 2026
- A novel humeral alignment guide for improving stem alignment in reverse shoulder arthroplasty: a retrospective comparative study.International orthopaedics · 2026
- The impact of lateralization and distalization shoulder angles-A systematic review of range of motion and clinical outcomes following reverse shoulder arthroplasty.Shoulder & elbow · 2026
- Does cemented versus uncemented humeral stem fixation influence outcomes in primary reverse shoulder arthroplasty? An updated systematic review and meta-analysis.Shoulder & elbow · 2026