The Effect of EVOLVE Radial Head Arthroplasty Stem Tilt on Clinical Outcomes.
Jimmy Tat, Amin Kheiran, Ruby Grewal, George S Athwal, Kenneth J Faber, Darren S Drosdowech, Graham J W King
Roth McFarlane Hand and Upper Limb Center (HULC), St. Joseph's Hospital, London, ON N6A 4L6, Canada. · Roth McFarlane Hand and Upper Limb Center (HULC), St. Joseph's Hospital, London, ON N6A 4L6, Canada. Electronic address: graham.king@sjhc.london.on.ca.
Key points
From the paper's conclusion- A cohort of patients with excessive RHA tilt cohort had worse overall clinical outcomes scores when compared to the control group, however they did not demonstrate higher rates of complications or revision surgery. In this patient cohort, excessive implant tilt developed late after surgery rather than in early follow-up.
Abstract
INTRODUCTION: Radial head arthroplasty (RHA) mal-alignment can occur when there is excessive tilt of the radial head stem relative to the radial canal. The etiology, clinical significance and management for increased RHA tilt is poorly understood. Our primary objective was to compare clinical outcomes in patients with excessive radiographic RHA tilt to controls. A secondary objective was to determine the relationship between radiographic stem alignment measurements and clinical outcomes. METHODS: We performed a retrospective chart review of patients who underwent a smooth stem RHA (EVOLVE, Wright Medical) between 1999 - 2021 for acute radial head fractures requiring isolated RHA. Patient demographics, clinical outcomes scores (PREE, QuickDASH, MEPI), range of motion, complications, reoperations, and radiographic measurements were compared between patients with excessive RHA tilt and controls. Radial head alignment was assessed using several parameters including radial neck-shaft angle, lateral overhang distance RHA implant, proximal radioulnar joint angle, radial neck length, radial neck width, radial neck cut angle, radial tuberosity width, and radiocapitellar line. Excessive RHA tilt was defined as patients with a high-neck shaft angle (greater than 1 Standard Deviation above the mean), while controls had a neck-shaft angle less than 1 Standard Deviation. Regression modelling was used to determine whether the radiographic alignment parameters correlate with of outcomes (PREE, QuickDASH, MEPI), complications and reoperations. A subgroup analysis compared radiographic tilt at 6 weeks and 1 year postoperatively. RESULTS: Sixty-one patients were included in the study, 10 patients with mal-alignment of the RHA and 51 patients in the control group. There was no significant difference in patient characteristics between groups (age, gender, handedness, smoking, time to surgery, follow-up time) (p>0.01). The tilt group demonstrated greater neck-shaft angles, RHA lateral overhang, PRUJ angles, and implant lucency, with shorter radial neck lengths and lower radial neck cut angles (all p<0.01). Patients with excessive tilt had worse clinical outcomes, including higher PREE and QuickDASH scores and lower MEPI scores (all p<0.01). Multiple linear regression showed overhang distance as a moderate predictor for PREE (R2=0.14, F1,54=9.7, p=0.003) and MEPI scores (R2=0.10, F1,53=7.3, p=0.009). Excessive tilt was more commonly observed at late rather than early follow-up. CONCLUSION: A cohort of patients with excessive RHA tilt cohort had worse overall clinical outcomes scores when compared to the control group, however they did not demonstrate higher rates of complications or revision surgery. In this patient cohort, excessive implant tilt developed late after surgery rather than in early follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term outcomes of radial head arthroplasty for complex radial head fractures.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Radial Head Arthroplasty for Radial Head Fracture Is Associated with a Lower Rate of Reoperation Than Open Reduction Internal Fixation: A Population-Based Cohort Study.Journal of shoulder and elbow surgery · 2026
- Glenohumeral radial mismatch and revision for aseptic loosening after anatomic total shoulder arthroplasty: a Dutch Arthroplasty Register study.Journal of shoulder and elbow surgery · 2026
- Coronal Alignment and Ulnar Deviation After Radial-Sided Lateral-Approach Silicone Arthroplasty of the Proximal and Distal Interphalangeal Joints: A Prospective Case Series.Hand (New York, N.Y.) · 2026
- Persistent Radial or Midcarpal Malalignment after Corrective Osteotomy Does Not Affect Functional Outcome.The journal of hand surgery Asian-Pacific volume · 2026
- Optimal Radial Head Prosthesis Sizing in Elbow Trauma: A Review of Anatomical Principles and Clinical Techniques.JBJS reviews · 2026