Clinical Outcomes of Concurrent Impella-Assisted High-Risk PCI and TAVR in Patients With Complex Coronary Artery Disease and Severe Aortic Stenosis.
Frederick Berro Rivera, Brenden Ingraham, Pietro Di Santo, Trevor Simard, Benjamin Hibbert, Mandeep Singh
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.
Key points
From the paper's conclusion- A single-session strategy of IA-CHIP followed by TAVR is feasible and safe in selected patients with complex coronary artery disease and severe aortic stenosis.
Abstract
BACKGROUND: Percutaneous management of high risk, percutaneous coronary intervention (PCI) needing mechanical support for complex coronary artery disease in patients needing transcatheter aortic valve replacement for severe aortic stenosis remains incompletely defined. We report on the feasibility and safety of a single-session strategy using Impella-assisted complex high-risk PCI (IA-CHIP) followed by transcatheter aortic valve replacement (TAVR). METHODS: We conducted a multicenter retrospective study of consecutive patients undergoing simultaneous IA-CHIP and TAVR at 3 tertiary centers between January 2015 and March 2026. All patients received mechanical circulatory support with percutaneous microaxial flow pump Impella CP (Abiomed) during PCI, followed by transfemoral TAVR in the same session. Baseline demographics, procedural characteristics, and clinical outcomes were collected. The primary endpoint was in-hospital complications, including death, stroke, major bleeding (Bleeding Academic Research Consortium types 2, 3, or 5), acute kidney injury, permanent pacemaker implantation, and vascular complications. RESULTS: A total of 12 patients were included (median age, 79.5 years [IQR, 77.0-81.2]; 91.7% male; median Charlson Comorbidity Index of 7 [IQR, 5.8-9]). Coronary lesions mainly involved left main disease in 66% of cases. Advanced calcium modification was required in 50% of cases. The median aortic valve area was 0.86 cm2, and median mean gradient was 38 mm Hg. Procedural success for IA-CHIP and TAVR was 100%. There were no in-hospital deaths, strokes, or major vascular complications. Conduction disturbances requiring permanent pacemaker implantation occurred in 25%. An acute kidney injury occurred in 16.7% of cases, with no requirement for dialysis. The majority of patients (91.7%) were discharged home. CONCLUSIONS: A single-session strategy of IA-CHIP followed by TAVR is feasible and safe in selected patients with complex coronary artery disease and severe aortic stenosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- When the “wrong” device is the right choice: Impella CP–assisted left main PCI as a bridge to TAVI in critical aortic stenosisCardiovascular Revascularization Medicine Interesting Cases · 2026
- Timing of revascularisation in patients undergoing high-risk percutaneous coronary intervention and Transcatheter aortic valve implantation: insights from the ASCoP registry.International journal of cardiology · 2026
- Comparison of Staged and Concomitant Percutaneous Coronary Intervention in Patients Undergoing Transcatheter Aortic Valve Replacement: A Retrospective Cohort Study.Annali italiani di chirurgia · 2026
- Complete Versus Incomplete Revascularization in Patients With Severe Aortic Stenosis Undergoing Complex, High-Risk PCI: Insights From the ASCoP Registry.Structural heart : the journal of the Heart Team · 2026
- A Stepwise Bail-Out Approach to Protected High-Risk PCI in a Complex CHIP Patient: A Case ReportComplications · 2026
- Timing of PCI in Patients Undergoing Transcatheter Aortic-Valve Implantation.The New England journal of medicine · 2026