Optimal Sheath for Single-Access Percutaneous Coronary Intervention With Impella CP Hemodynamic Support.
Ravi Thakker, Adnan Khalif, Ying Xu, Seth Bilazarian, Dana Bentley, J Dawn Abbott, Mario Iannaccone, Jason Wollmuth,
Section of Cardiovascular Medicine, Department of Internal Medicine, Yale School of Medicine, New Haven, Connecticut. · Allegheny Health Network Cardiovascular Institute, Pittsburgh, Pennsylvania.
Key points
From the paper's conclusion- The Impella LP Companion sheath demonstrated the best torqueability and least effort in advancing the guide catheters, while the Prelude Roadster and Destination also performed well on these metrics. The Prelude IDeal and Glidesheath were good options for single-access because of their smaller outer diameters and hydrophilic coating and were easiest for insertion/removal through the 14F LP sheath.
Abstract
BACKGROUND: Single-access percutaneous coronary intervention (PCI) with the Impella CP (Abiomed) has increased in prevalence. Despite this, the optimal PCI sheath remains unknown. We characterized the optimal 7F PCI sheath using the single-access technique. METHODS: The outer diameter measurement of the sheaths was performed using a Keyence 2-axis laser micrometer (Keyence). The force needed to insert the sheath and the torqueability of the guide catheter were assessed using the Mark-10 M5i Advanced Digital Force/Torque Indicator (Mark-10 Corporation) on a simulated single-access setting in a simulated skin pad. The sample size was determined to be 5 sheaths for each test. RESULTS: The BRITE TIP 11 cm (Cordis), BRITE TIP 35 cm (Cordis), and Destination sheath (Terumo) had the largest outer diameters; the Prelude IDeal (Merit Medical) and Terumo Glidesheath (Terumo) had the smallest outer diameters. The Glidesheath was easiest for insertion/removal, followed by the Prelude IDeal and Impella Low Profile (LP) Companion sheath (Abiomed). The Impella LP Companion, Prelude Roadster (Merit Medical), and Destination sheaths allowed for the best torqueability and lowest force to remove the guide catheter. The longer Impella LP Companion sheath did not impact torqueability, but the removal force increased by 50% compared with the shorter Impella LP Companion sheath. CONCLUSION: The Impella LP Companion sheath demonstrated the best torqueability and least effort in advancing the guide catheters, while the Prelude Roadster and Destination also performed well on these metrics. The Prelude IDeal and Glidesheath were good options for single-access because of their smaller outer diameters and hydrophilic coating and were easiest for insertion/removal through the 14F LP sheath.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advancement speed and sheath caliber influence peak axial insertion force and ureteral injury during ureteral access sheath placement: an ex vivo porcine study.Urolithiasis · 2026
- A Stepwise Bail-Out Approach to Protected High-Risk PCI in a Complex CHIP Patient: A Case ReportComplications · 2026
- When the “wrong” device is the right choice: Impella CP–assisted left main PCI as a bridge to TAVI in critical aortic stenosisCardiovascular Revascularization Medicine Interesting Cases · 2026
- Comparison of two blunt dissection sheath insertion techniques in peripherally inserted central catheter placement: a randomized non-inferiority trial.Frontiers in medicine · 2026
- Single-Catheter Versus Conventional Two-Catheter Primary PCI in STEMI: A 1:1 Propensity Score-Matched Cohort Study.Cardiovascular therapeutics · 2026
- In-Vitro Comparison of Cyclic Aspiration and Superbore Aspiration Catheters to Conventional 6Fr Aspiration for LVO Stroke.Clinical neuroradiology · 2026