Journal of the Society for Cardiovascular Angiography & Interventions

High-Fidelity Simulation for Assessing Catheterization-Based Skills Among Trainees.

Nicholas B Mitchell, Luai Madanat, Shazil Mahmood, Justin Armstrong, Michael Gallagher, Robert D Safian, Ryan D Madder

Center for Innovation & Research in Cardiovascular Diseases, Department of Cardiovascular Medicine, William Beaumont University Hospital, Corewell Health East, Royal Oak, Michigan.

Computational

Key points

From the paper's conclusion
  • Using a high-fidelity simulator, increasing operator experience was associated with less time to coronary catheter engagement. Simulation was associated with a significant increase in trainee confidence in performing coronary catheter engagement.

Abstract

BACKGROUND: Simulation-based training for coronary angiography has not been widely adopted, and an operator's skillset should be accurately reflected in a simulation-based task. The purpose of this study is to determine whether increasing levels of clinical experience were associated with improved performance and whether trainees' confidence improved with use of a high-fidelity simulator. METHODS: Physicians with different catheterization experience (internal medicine residents, first- through third-year cardiology fellows, interventional fellows, and attending interventional cardiologists) performed multiple coronary artery catheter engagements on a high-fidelity endovascular simulator. The primary outcome was coronary engagement time (from the ascending aorta to coronary). Trainees completed presimulation and postsimulation surveys assessing confidence in catheter engagement (10-point Likert scale: 1, no confidence; 10, supreme confidence). RESULTS: Across 240 catheter engagements by 24 physicians, median coronary engagement time was 37 seconds (IQR, 22-64). Engagement times were longer on the right coronary artery (42 seconds [22-70]) than on the left (34 seconds [21-56]; P = .04). Engagement time decreased with increasing operator experience (P trend < .001). Baseline confidence increased with training stage (P trend < .001), and among all trainees combined, confidence in catheter engagement improved after simulation (6 [2-7] vs 7 [5-8]; P = .01). CONCLUSIONS: Using a high-fidelity simulator, increasing operator experience was associated with less time to coronary catheter engagement. Simulation was associated with a significant increase in trainee confidence in performing coronary catheter engagement.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers