Journal of psychiatric research

Challenges in PTSD screening among depressed outpatients: Diagnostic performance and psychometric structure of the PC-PTSD-5 in a Chilean clinical sample.

Sergio Gloger, Pablo Martínez, Dante Diez de Medina, M Victoria Chacón, Cristián Cáceres, Rebeca Corbalán, Eduardo Sánchez, Carolina Santis

Psicomedica, Clinical & Research Group, Santiago, Chile; Departamento de Psiquiatría y Salud Mental Campus Oriente, Universidad de Chile, Santiago, Chile. · Psicomedica, Clinical & Research Group, Santiago, Chile; Centro de Estudios en Psicología Clínica y Psicoterapia (CEPPS), Facultad de Psicología, Universidad Diego Portales, Santiago, Chile; McGill Group for Suicide Studies, Douglas Mental Health University Institute, Department of Psychiatry, McGill University, Montreal, Québec, Canada. Electronic address: pablo.martinez@udp.cl.

Observational · n=263

Key points

From the paper's conclusion
  • The PC-PTSD-5 showed modest accuracy and a high false-positive rate among depressed outpatients. It may be useful as an initial case-finding aid: positive screens require diagnostic assessment. A cut-off of ≥4 reduced false positives but missed PTSD cases and requires replication. The findings support context-sensitive use of the original instrument.

Abstract

BACKGROUND: Posttraumatic stress disorder (PTSD) frequently co-occurs with depression, may remain undetected and affect treatment planning. Brief PTSD screens are not well established in depressed outpatients, particularly in Latin America. METHODS: We conducted a prospective validation study in 263 adults receiving outpatient care for a depressive episode in Santiago, Chile. The Chilean Spanish Primary care PTSD Screen for DSM-5 (PC-PTSD-5) was evaluated against PTSD diagnosis established using DSM-5 criteria. Diagnostic accuracy was assessed using receiver operating characteristics (ROC) analyses, performance was examined overall and stratified by depression severity. Internal structure was examined using WLSMV confirmatory factor analysis. RESULTS: PTSD prevalence was 27.8%. The PC-PTSD-5 showed modest discrimination (AUC = 0.688; 95% CI, 0.617-0.759). At ≥3, sensitivity was 72.6% and specificity was 60.5%. At ≥4, specificity increased to 73.2% and accuracy to 70.7%, while sensitivity decreased to 64.4%. AUCs did not differ by depression severity (p = 0.286). The five-item model showed mixed fit, with a weak loading for emotional numbing. The four-item model showed improved internal structure but did not improve discrimination (AUC = 0.687; p = 0.839). LIMITATIONS: The single-site design and limited subgroup and psychometric samples restrict generalizability. CONCLUSIONS: The PC-PTSD-5 showed modest accuracy and a high false-positive rate among depressed outpatients. It may be useful as an initial case-finding aid: positive screens require diagnostic assessment. A cut-off of ≥4 reduced false positives but missed PTSD cases and requires replication. The findings support context-sensitive use of the original instrument.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Challenges in PTSD screening among depressed outpatients: Diagnostic performance and psychometric structure of the PC-PTSD-5 in a Chilean clinical sample — Science Skim