Impact of an Ultrasound-First Clinical Care Guideline on Imaging Utilization and Diagnostic Performance in Suspected Midgut Volvulus.
Johanna M Borst, Daria S Dzakovic, Mallory N Perez, Cynthia K Rigsby, Ellen C Benya, Mehul V Raval
Department of Surgery, Northwestern University Feinberg School of Medicine, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA. Electronic address: johanna-borst@northwestern.edu. · Department of Surgery, Northwestern University Feinberg School of Medicine, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA.
Key points
From the paper's conclusion- An ultrasound-first CCG for volvulus increased ultrasound utilization with excellent accuracy among definitive reads. For patients with inconclusive ultrasounds (37.8%), obtaining subsequent UGI studies did not result in operative delays in this limited sample.
Abstract
BACKGROUND: Infants with suspected midgut volvulus are typically evaluated with an upper gastrointestinal (UGI) contrast series; we implemented an ultrasound-first clinical care guideline (CCG) and evaluated its impact on imaging utilization, diagnostic accuracy, and timeliness of care. METHODS: Single-center retrospective pre-post study of infants ≤1 year evaluated for volvulus (January 2022-September 2025). Outcomes included ultrasound utilization, diagnostic performance, time to imaging interpretation, and time to operating room (OR). RESULTS: Among 151 patients (96 pre- and 55 post-CCG), 8 had operatively confirmed volvulus. Of the 6 taken immediately to surgery, volvulus was identified by ultrasound alone in 3, UGI alone in 2, and concordant ultrasound and UGI in 1. Ultrasound-first utilization increased after implementation. Ultrasound (n=45) demonstrated 100% sensitivity (4/4) and specificity (24/24) among definitive interpretations, with a 37.8% inconclusive rate (17/45); 1 inconclusive examination was confirmed as volvulus by UGI and operation. UGI (n=143) demonstrated 83.3% sensitivity (5/6; 1 volvulus missed) and 100% specificity (133/133), with a 2.8% inconclusive rate (4/143). Median time from imaging order to definitive interpretation was 116 minutes (IQR 90-164; n=107) for UGI first and 92 minutes (IQR 70-118; n=24) for US first. Median time from imaging order to OR was 102 minutes (n=3) for ultrasound-only, 178 minutes (n=2) for UGI-only, and 128 minutes (n=1) for both. CONCLUSIONS: An ultrasound-first CCG for volvulus increased ultrasound utilization with excellent accuracy among definitive reads. For patients with inconclusive ultrasounds (37.8%), obtaining subsequent UGI studies did not result in operative delays in this limited sample.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- International practice patterns in the use of ultrasound as first-line imaging for suspected midgut volvulus in children: a joint society for pediatric radiology-European society of paediatric radiology survey.Pediatric radiology · 2026
- Ultrasound for diagnosing paediatric intestinal malrotation and midgut volvulus: a retrospective study in a single-centre high-suspicion cohort.Frontiers in pediatrics · 2026
- A standardized universal protocol for using adjunct abdominal ultrasound at the time of diagnosis for suspected necrotizing enterocolitisPediatric Radiology · 2025
- Development and internal validation of an objective diagnostic model based on gastric filling ultrasonography for gastric stump carcinoma: a TRIPOD-compliant retrospective study.Frontiers in medicine · 2026
- Combining abdominal ultrasound and radiography for surgical risk stratification in necrotising enterocolitis: a prospective cohort pilot studyArchives of Disease in Childhood Fetal & Neonatal · 2026
- Gastrointestinal point-of-care ultrasound for enteral nutrition management in critically ill adults: a scoping review.Frontiers in nutrition · 2026