Setting the target measurement uncertainty for the analytical target profile using Monte Carlo simulation and guard bands.
Jose Huertas, Jane Weitzel, Pierre Lebrun, Amanda M Guiraldelli, Antonio Hernandez-Cardoso
Del Hueso 554, E204 Granjas Coapa, Tlalpan, Mex City, CP 14330, Mexico. · United States Pharmacopeia, Twinbrook Parkway, Rockville, MD 12601, USA.
Key points
From the paper's conclusion- The article shows that Monte Carlo simulation enables the TMU to be selected based on a data-driven assessment of performance, capability, and risk, ensuring that the analytical procedure is fit for its intended purpose.
Abstract
An analytical procedure produces a reportable result. It represents the laboratory's best estimate of the true value, but it always comes with some uncertainty. The approach in this article enables a data-driven, lifecycle-based assessment of analytical procedures, supporting both development and ongoing assurance that results remain fit for their intended purpose. This article provides a practical framework for linking the purpose of an analytical procedure to its required measurement performance using target measurement uncertainty (TMU), Monte Carlo simulation, and quantified probabilities of correct and incorrect decisions. The article shows that Monte Carlo simulation enables the TMU to be selected based on a data-driven assessment of performance, capability, and risk, ensuring that the analytical procedure is fit for its intended purpose. For various values of the Ppk index, the authors calculated the contribution of analytical procedure variance, expressed as the Overall Variance Method Contribution (OVMC). Finally, a graphical approach was used to evaluate whether a process is performing as it was developed and validated. With the fit for purpose approach to ensuring analytical procedures are developed, qualified, and perform as needed during routine use, TMU takes on an important role. It is used to help calculate the probability of being wrong. This probability defines the acceptability of the analytical procedure's output, the reportable results. A sequential approach to setting the TMU for the guard band approach is presented.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metrological Evaluation of Metopimazine HPLC Assay: ISO-GUM and Monte Carlo Simulation ApproachesPharmaceutics · 2025
- Collaborative trial in sampling for validation of measurement procedures that include samplingAccreditation and Quality Assurance · 2026
- Standardized Estimation of Measurement Uncertainty in Clinical Chemistry Using ISO 20914.Clinical laboratory · 2026
- Analytical Performance Specifications Derived from External Quality Assessment Data: Comparison with Biological Variation-Based Models for Intermediate Precision Assessment.Annals of laboratory medicine · 2026
- Assigned-Value Uncertainty in Limited-Participant Proficiency Testing: Monte Carlo Evaluation of ISO 13528 Estimators in an Industrial Calibration ScenarioMetrology · 2026
- Analytical performance specifications in the clinical laboratory: Historical evolution, conceptual foundations and a practical decision framework.Clinical biochemistry · 2026