From the paper's conclusion
  • A novel strategy integrating biomimetic extracted substances (BES) with peak-cutting fractionation was developed to screen activity-correlated quality markers (Q-markers) for Jingu Tongxiao Pill (JGTXP), a traditional Chinese medicine formula clinically used for osteoarthritis with unclear holistic bioactive basis and single quality control indicators predominantly relying on Salvia miltiorrhiza B

Abstract

A novel strategy integrating biomimetic extracted substances (BES) with peak-cutting fractionation was developed to screen activity-correlated quality markers (Q-markers) for Jingu Tongxiao Pill (JGTXP), a traditional Chinese medicine formula clinically used for osteoarthritis with unclear holistic bioactive basis and single quality control indicators predominantly relying on Salvia miltiorrhiza Bunge (Danshen). Sequential in vitro metabolism simulating gastrointestinal digestion, gut microbiota biotransformation, and hepatic S9 incubation generated a BES mimicking in vivo systemic exposure. Following ultra-high-performance liquid chromatography (UHPLC)-Q-Exactive Orbitrap mass spectrometry (MS) characterization, the BES was fractionated into 30 segments via high-performance liquid chromatography (HPLC) peak-cutting for anti-inflammatory activity screening in lipopolysaccharide (LPS)-stimulated RAW 264.7 macrophages, and multivariate comparison enabled the back-tracing of 15 Q-markers to their herbal origins. A rapid UHPLC-tandem mass spectrometry (MS/MS) method operating in multiple reaction monitoring (MRM) mode was then established for simultaneous their simultaneous quantification. Chromatographic separation was achieved on a Phenomenex Synergi Polar-RP column (150 mm×2 mm, 4 μm) using a gradient of 0.1% formic acid in water and acetonitrile at a flow rate of 0.3 mL/min. The method was fully validated, exhibiting excellent linearity (r > 0.994), precision (relative standard deviation, RSD ≤ 15%), repeatability (RSD < 6.21%), and accuracy (recoveries 85.1-113.1%). Quantification of 20 commercial batches revealed considerable batch-to-batch variability (0.41-15 221.83 μg/g; with limits of detection ranging from 0.00625 to 25 ng/mL). The combined BES-guided screening and UHPLC-MS/MS quantification provides a physiologically relevant and robust analytical framework for upgrading the quality standard of complex herbal formulations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Screening of quality markers of Chinese medicine preparation by combining biomimetic extracted substances and peak-cutting strategy: Jingu Tongxiao Pills as a case — Science Skim