Journal of stomatology, oral and maxillofacial surgery

Evaluation of the Diagnostic Performance of an Implant Marginal Bone Loss Measurement Method Based on Deep Learning.

Huaxin Sui, Hongyu Fu, Zhihan Zhang, Jing Liao, Hu Chen

Department of Stomatology, Peking University First Hospital, Xicheng District, Beijing 100034, China. · Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Haidian District, Beijing 100081, China.

Computational · n=144

Key points

From the paper's conclusion
  • The YOLOv8-pose model shows excellent diagnostic performance, especially for early mild bone loss. This artificial intelligence tool serves as an auxiliary early-screening tool rather than a comprehensive diagnostic tool covering all severities of bone loss; it can assist clinicians in standardized, efficient, and early screening assessment of peri-implant diseases.

Abstract

OBJECTIVES: To evaluate the diagnostic performance of the YOLOv8-pose model for automated measurement of mesial and distal peri-implant marginal bone loss on periapical radiographs. METHODS: In this retrospective study, 162 images were divided into training (n=144) and validation (n=18) sets; 46 images formed an independent test set. Six anatomical key points were annotated and verified as the gold standard. The model was tested at thresholds of bone loss ≥0.5 mm, ≥1.0 mm, and ≥2.0 mm. F1-score was additionally calculated for each threshold. RESULTS: At the 0.5 mm threshold, the model achieved 95.35% sensitivity, 100% specificity, 100% positive predictive value (PPV), and 90.7% mesial-distal diagnostic consistency. At the 1.0 mm threshold, sensitivity was 91.67%, specificity 82.14%, PPV 73.33%, and consistency 58.14%. At the 2.0 mm threshold, sensitivity dropped to 30.43%, while specificity remained high at 95.97%, with 53.85% PPV and 72.1% consistency. Median key point localization errors ranged from 0.76 mm to 1.05 mm, with no statistically significant difference among groups (P>0.05). CONCLUSIONS: The YOLOv8-pose model shows excellent diagnostic performance, especially for early mild bone loss. This artificial intelligence tool serves as an auxiliary early-screening tool rather than a comprehensive diagnostic tool covering all severities of bone loss; it can assist clinicians in standardized, efficient, and early screening assessment of peri-implant diseases. ADVANCES IN KNOWLEDGE: This study validates a keypoint-based deep learning approach for automated and consistent measurement of peri-implant marginal bone loss on periapical radiographs, supporting early objective screening-level assessment of radiographic peri-implant marginal bone-loss changes for clinician reference.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Evaluation of the Diagnostic Performance of an Implant Marginal Bone Loss Measurement Method Based on Deep Learning — Science Skim