Clinical Success, Mechanical Stability, and Peri-Implant Radiographic Characteristics of Orthodontic Mini-Screws Under Immediate Versus Delayed Loading: A Retrospective Comparative Study.

Yumeng Song, Lishuo Yang

Department of Stomatology, Dalian Qixianling Community Hospital, Dalian 116027, Liaoning, China. · Department of Stomatology, The Second Affiliated Hospital of Dalian Medical University, Dalian 116027, Liaoning, China. Electronic address: LishuoYang58634@163.com.

Observational

Key points

From the paper's conclusion
  • Immediate and delayed loading of orthodontic mini-screws were associated with similar observed clinical success proportions and mechanical stability measurements, with no clear between-group differences in the available peri-implant radiographic findings. These results do not establish equivalence between loading protocols or directly demonstrate histological osseointegration.

Abstract

OBJECTIVE: To compare clinical success, mechanical stability, and peri-implant radiographic characteristics of orthodontic mini-screws subjected to immediate loading (IL) versus delayed loading (DL). METHODS: This retrospective comparative study evaluated the clinical records of 100 orthodontic patients who received one orthodontic mini-screw in the maxilla or mandible. Implant stability was assessed using the Implant Stability Quotient (ISQ) and Periotest values (PTV) at baseline and at 1, 3, 6, 12, and 24 months. Peri-implant radiographic measurements were obtained using cone-beam computed tomography (CBCT) at the documented assessment time points. Failures included screw loss, mobility > grade 1, persistent inflammation > 2 weeks, or pain requiring removal. Survival was analyzed with Kaplan-Meier curves. RESULTS: Clinical success was recorded in 47 of 50 mini-screws (94.0%) in the IL group and 46 of 50 (92.0%) in the DL group, with 3 and 4 documented failures, respectively. Kaplan-Meier analysis was used to assess time to clinical failure. ISQ values showed a transient decrease at 1 month in both groups, followed by progressive recovery and stabilization by 6 months. PTV values changed inversely to ISQ, showing a corresponding temporary increase at 1 month and subsequent improvement thereafter. CBCT-measured peri-implant bone density increased progressively at 6, 12, and 24 months compared with baseline in both groups. Insertion torque and removal torque values were similar between the two loading protocols. CONCLUSIONS: Immediate and delayed loading of orthodontic mini-screws were associated with similar observed clinical success proportions and mechanical stability measurements, with no clear between-group differences in the available peri-implant radiographic findings. These results do not establish equivalence between loading protocols or directly demonstrate histological osseointegration.

Read the paper