Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia

Do we have an appropriate cut-off for the kappa free light chain index in multiple sclerosis diagnosis? a real-world single-center comparison with oligoclonal bands.

Milovan Roganovic, Tanja Antunovic, Balsa Vujovic, Ljiljana Radulovic, Sandra Vujovic, Mladen Debeljevic, Jevto Erakovic, Zilha Idrizovic,

Clinic for Neurology, Clinical Center of Montenegro, Ljubljanska bb, Podgorica, Montenegro; Faculty of Medicine, University of Montenegro, Krusevac bb, Podgorica, Montenegro. Electronic address: mil.roganovic@gmail.com. · Centre for Clinical Laboratory Diagnostics, Clinical Center of Montenegro, Ljubljanska bb, Podgorica, Montenegro.

Observational · n=140

Key points

From the paper's conclusion
  • The KFLC index showed high diagnostic accuracy for MS in a heterogeneous real-world neurological cohort. The locally derived cut-off of 9.3 provided a favorable balance between sensitivity and specificity and identified a clinically relevant subgroup of OCB-negative patients with MS. These findings support further evaluation of the study-derived threshold in independent cohorts and contextual interpretation of KFLC and OCB within the overall diagnostic assessment.

Abstract

BACKGROUND: The kappa free light chain (KFLC) index has emerged as a quantitative marker of intrathecal immunoglobulin synthesis and is increasingly used in the diagnostic evaluation of multiple sclerosis (MS). However, the optimal diagnostic threshold remains uncertain and may vary across clinical populations. We aimed to evaluate the diagnostic performance of the KFLC index in a real-world neurological cohort, compare it with oligoclonal bands (OCBs), and determine a locally optimal cut-off value. METHODS: We conducted a retrospective, single-center study including 140 patients who underwent lumbar puncture during routine neurological diagnostic work-up. Sixty-four patients were diagnosed with MS and 76 with other neurological disorders. Demographic and cerebrospinal fluid parameters, including OCB status and KFLC index, were analyzed. Diagnostic performance was assessed using receiver operating characteristic (ROC) analysis, and the optimal KFLC cut-off was determined using Youden's index alongside the established 6.1 consensus cut-off, with 9.3 selected to maximize diagnostic specificity. Agreement between dichotomized KFLC results and OCB status was evaluated using Cohen's kappa. RESULTS: The KFLC index was significantly higher in patients with MS than in non-MS patients [median 43.4 (IQR 16.6-88.1) vs. 1.8 (IQR 1.4-2.8), p<0.001]. ROC analysis showed high diagnostic accuracy for the KFLC index, with an AUC of 0.954 (95% CI 0.919-0.990), compared with 0.831 (95% CI 0.756-0.905) for OCB status. A locally optimal KFLC index cut-off of 9.3 yielded 89.1% sensitivity, 96.0% specificity, a positive predictive value of 95.0%, a negative predictive value of 91.3%, and an overall accuracy of 92.9%. OCB positivity was observed in 68.8% of MS patients and 2.6% of non-MS patients. KFLC and OCB results were concordant in 122 of 140 patients (87.1%), with substantial agreement (Cohen's κ=0.73). Among 16 OCB-negative patients with KFLC index values above the selected threshold, 13 were ultimately diagnosed with MS. CONCLUSIONS: The KFLC index showed high diagnostic accuracy for MS in a heterogeneous real-world neurological cohort. The locally derived cut-off of 9.3 provided a favorable balance between sensitivity and specificity and identified a clinically relevant subgroup of OCB-negative patients with MS. These findings support further evaluation of the study-derived threshold in independent cohorts and contextual interpretation of KFLC and OCB within the overall diagnostic assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Do we have an appropriate cut-off for the kappa free light chain index in multiple sclerosis diagnosis? a real-world single-center comparison with oligoclonal bands — Science Skim