科研速览继续刷下去 →
◆ Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia2026-09-17

Agreement of Cercare artificial intelligence with neuroradiologist interpretation and Vitrea CT perfusion outputs in acute ischaemic stroke: A dual-centre retrospective study.

Kausik Chatterjee, Allam Harfoush, Saranya Kalyanasundaram Lakshmi, Kumar Pulapula, Anastasia Liaretidou, Parthasarathy Karunakaran, Ciprian Rusu, Patricia O'keefe, Fathalla Elnagi

一句话结论

Cercare showed substantial agreement with expert CTA interpretation. Quality control materially influenced CTP agreement estimates, and residual individual-patient variability, particularly for penumbra and treatment-threshold classification, indicates that outputs should not be regarded as interchangeable. The DAWN-derived analysis represents a threshold classification rather than full trial eligibility. CMRO2 findings are exploratory and hypothesis-generating and require prospective validation.

原始摘要(原文)
PURPOSE: To assess agreement between Cercare artificial intelligence (AI) and expert neuroradiologist interpretation for CT angiography (CTA) large vessel occlusion (LVO) detection, and to compare Cercare and Vitrea CT perfusion (CTP) outputs in acute ischaemic stroke. METHODS: This dual-centre retrospective study included 214 adults undergoing multimodal CT for suspected acute ischaemic stroke. LVO agreement was assessed in 162 CTA datasets using consultant neuroradiologist interpretation as the comparator; no angiographic or consensus reference standard was used. The quality-controlled primary CTP analysis included 196 paired datasets after exclusion of five studies with documented technical compromise; an all-output sensitivity analysis included 201 datasets. Treatment classification was assessed in 65 quality-controlled neuroradiologist-confirmed LVO cases with paired perfusion outputs, with an all-output sensitivity analysis in 67 cases. Cercare-derived cerebral metabolic rate of oxygen (CMRO2) volumes were examined in exploratory, hypothesis-generating analyses against perfusion core volumes and discharge modified Rankin Scale (mRS). RESULTS: Cercare showed positive percent agreement of 82.3% (95% CI 71.0-89.8) and negative percent agreement of 83.0% (74.5-89.1) with neuroradiologist interpretation, with substantial agreement (kappa = 0.641). In the quality-controlled CTP cohort, core limits of agreement were - 34.7 to 30.1 mL (ICC 0.930) and penumbra limits were - 94.6 to 104.7 mL (ICC 0.812). Inclusion of five technically compromised studies widened the corresponding all-output limits to - 90.5 to 86.4 mL and - 191.4 to 219.5 mL. In 65 quality-controlled LVO patients, agreement was 93.8% for EXTEND-IA-style imaging mismatch and 87.7% for DAWN-style clinical-core mismatch classification. In exploratory, hypothesis-generating analyses, CMRO2 correlated with Vitrea core (ρ = 0.758-0.787) and discharge mRS (ρ = 0.390-0.401). CONCLUSION: Cercare showed substantial agreement with expert CTA interpretation. Quality control materially influenced CTP agreement estimates, and residual individual-patient variability, particularly for penumbra and treatment-threshold classification, indicates that outputs should not be regarded as interchangeable. The DAWN-derived analysis represents a threshold classification rather than full trial eligibility. CMRO2 findings are exploratory and hypothesis-generating and require prospective validation.
读原文 ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文

Agreement of Cercare artificial intelligence with neuroradiologist interpretation and Vitrea CT perfusion outputs in acute ischaemic stroke: A dual-centre retrospective study. — 科研速览 Science Skim