Clinical utility of cerebrospinal fluid MOG-IgG testing in patients with paired serum and CSF testing.
Thor Linnet, Farrah J Mateen, Shailee S Shah
Department of Neurology, Northwestern University, USA. Electronic address: Thor.linnet@regionh.dk. · Department of Neurology, Northwestern University, USA. Electronic address: farrah.mateen@northwestern.edu.
Key points
From the paper's conclusion- CSF MOG-IgG testing by commercially-available, fixed-CBA provided little incremental diagnostic yield over serum testingand incurred substantial cost in a single-center, retrospective study. Unlike prior studies using live CBA, which showed higher sensitivity and detected CSF-restricted cases, our findings support limiting CSF testing to selected seronegative patients, ideally with live CBA and performed similarly to prior studies on CSF MOG-IgG fixed-CBA. Larger, multi-center studies are needed to corroborate this data.
Abstract
BACKGROUND: The diagnostic value of CSF MOG-IgG testing remains uncertain, particularly when performed using a commercially available fixed cell-based assay. OBJECTIVES: To evaluate the diagnostic utility and cost of cerebrospinal fluid (CSF) myelin oligodendrocyte glycoprotein immunoglobulin G (MOG-IgG) testing using commercially available fixed cell-based assay (CBA) in paired serum-CSF samples. METHODS: A retrospective diagnostic accuracy study at a large academic center was conducted on adult patients tested for MOG-IgG in serum and/or CSF between January 2024 and February 2026. Paired samples were defined as serum and CSF samples obtained within 14 days. Serum testing used live CBA and CSF testing fixed CBA. Sensitivity, specificity, predictive values, likelihood ratios, and cost estimates were assessed. RESULTS: Among 94 patients with paired testing, 17 (18.1%) tested positive in serum of which 13 fulfilled MOGAD criteria. Across all paired samples, 3 patients tested positive in CSF and they also tested positive in serum and fulfilled MOGAD criteria. No patient was MOG-IgG CSF positive while negative in serum. CSF fixed CBA sensitivity was 23.1%, specificity 100.0%, and negative likelihood ratio 0.77. CONCLUSIONS: CSF MOG-IgG testing by commercially-available, fixed-CBA provided little incremental diagnostic yield over serum testingand incurred substantial cost in a single-center, retrospective study. Unlike prior studies using live CBA, which showed higher sensitivity and detected CSF-restricted cases, our findings support limiting CSF testing to selected seronegative patients, ideally with live CBA and performed similarly to prior studies on CSF MOG-IgG fixed-CBA. Larger, multi-center studies are needed to corroborate this data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MOG-IgG in the cerebrospinal fluid: a narrative review.Journal of neurology · 2026
- Beyond Positivity: Understanding and Interpreting MOG-IgG Testing in MOGAD.Journal of clinical neurology (Seoul, Korea) · 2026
- Performance of the international 2023 myelin oligodendrocyte glycoprotein antibody-associated disease panel criteria in a Japanese cohort: combined assessment of myelin oligodendrocyte glycoprotein immunoglobulin G in serum and CSF.Brain communications · 2026
- "Low-Positive" MOG-IgG Cases Among Adults With a First Event Suggestive of Multiple Sclerosis.Annals of clinical and translational neurology · 2026
- Limited availability of live CBA for MOG-IgG testing and its consequences for the diagnosis and treatment of MOGAD in Latin American countriesMultiple Sclerosis and Related Disorders · 2026
- TRUE-MOGAD Score: A Novel Scoring System to Identify MOGAD Among Positive MOG-IgG Test Results.Neurology(R) neuroimmunology & neuroinflammation · 2026