Large-domain histology-based diffusion MRI simulation via independent local simulations.
Iris A Kohler, Lei Zheng, Tristan A Kuder, Oliver Gödicke, Mark E Ladd, Jürgen Hesser
Mannheim Institute for Intelligent Systems in Medicine (MIISM), Heidelberg University, 68167, Mannheim, Germany; CZS Heidelberg Initiative for Model-Based AI (MBAI), Heidelberg University, 69117, Heidelberg, Germany. Electronic address: iris.kohler@medma.uni-heidelberg.de. · Mannheim Institute for Intelligent Systems in Medicine (MIISM), Heidelberg University, 68167, Mannheim, Germany; CZS Heidelberg Initiative for Model-Based AI (MBAI), Heidelberg University, 69117, Heidelberg, Germany.
Key points
From the paper's conclusion- For an 800 μm × 800 μm histology-based domain, the aggregated signal differed by 0.07% from the corresponding full-domain finite element simulation while reducing wall-clock time from several days to hours and maintaining bounded memory usage independent of global domain size.
Abstract
Diffusion MRI simulations based on realistic tissue microstructure provide a means to validate biophysical models and optimize acquisition protocols, but their computational cost restricts most studies to domains far smaller than a clinical voxel. The objective of this study was to develop an automated and scalable framework that converts whole-slide histology into diffusion MRI simulations at clinically relevant spatial scales while remaining feasible on standard workstation hardware. We present an end-to-end pipeline integrating two-dimensional whole-slide cell segmentation, mesh generation, and finite element Bloch-Torrey simulation. To enable simulations at large spatial scales without prohibitive memory growth, we introduce a subdomain tiling strategy in which the tissue domain is partitioned into extended subdomains simulated independently under no-flux boundary conditions. Signals are aggregated only from the central regions of each subdomain to minimize boundary artifacts. For an 800 μm × 800 μm histology-based domain, the aggregated signal differed by 0.07% from the corresponding full-domain finite element simulation while reducing wall-clock time from several days to hours and maintaining bounded memory usage independent of global domain size. When applied to a 2016 μm × 2016 μm heterogeneous region approximating the in-plane dimensions of a clinical voxel, the apparent diffusion coefficient obtained from the full domain differed from values computed in smaller dense and sparse subregions, demonstrating the influence of structural heterogeneity at clinically relevant scales on derived diffusion metrics. The proposed framework establishes an automated and memory-stable approach for generating diffusion MRI simulations directly from routine histology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- NOZOMI: a GPU-accelerated Monte-Carlo numerical approach for microstructure diffusion imaging.Physics in medicine and biology · 2026
- IMG-30 Noninvasive Mapping of Tumor Cell Size Distribution Using Deep Learning and Susceptibility-Contrast MRINeuro-Oncology · 2026
- A Time-Dependent Diffusion MRI Framework for Clinical Characterisation of Human Brain Cellular ArchitecturemedRxiv · 2026
- AI-based reconstruction from low-resolution acquisitions for diffusion MRI: evaluation of FOD similarity.Radiological physics and technology · 2026
- Towards Clinical Translation of Intravoxel Incoherent Motion MRI : Acquisition and Analysis Consensus RecommendationsJournal of Magnetic Resonance Imaging · 2026
- A GPU-Accelerated MRI Simulator for Synthetic Image Generation.Journal of imaging · 2026