Radiation dose reduction and diagnostic performance of reconstruction techniques in CT enterography: A systematic review and meta-analysis.
Shivanath Shanbhag, Nitika C Panakkal, Prakashini Koteshwara, Suresh Sukumar, Priya Pattath Sankaran, Visakh Thrivikraman Nair, Jyoti Garg
Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India. Electronic address: shivanath.mchpmpl2024@learner.manipal.edu. · Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India. Electronic address: nitika.cp@manipal.edu.
Key points
From the paper's conclusion- Advanced reconstruction techniques, particularly IR, can enable substantial radiation dose reduction while maintaining acceptable diagnostic performance. However, substantial heterogeneity, small-study effects, and low certainty of evidence warrant cautious interpretation. Further multicenter studies are needed to establish optimal reconstruction and acquisition strategies.
Abstract
INTRODUCTION: CT enterography (CTE) provides comprehensive assessment of small-bowel disease but may result in substantial radiation exposure, particularly in patients requiring repeated examinations. Advanced reconstruction techniques may enable radiation dose reduction while maintaining diagnostic performance. METHODS: PubMed, Scopus, Embase, Web of Science, and CINAHL were searched from January 2000 to May 2026. The review followed PRISMA 2020, and PRISMA-DTA was used for the diagnostic accuracy component. Studies evaluating filtered back projection (FBP), iterative reconstruction (IR), model-based iterative reconstruction (MBIR), or deep learning reconstruction (DLR) in adults undergoing CTE were included. Radiation dose outcomes were synthesized using random-effects meta-analysis, with subgroup and meta-regression analyses performed where appropriate. Diagnostic accuracy was assessed using a bivariate random-effects model. Risk of bias and certainty of evidence were assessed using appropriate tools and GRADE, respectively. RESULTS: Fifteen studies were included. Pooled CTDIvol was 9.32 mGy (95% CI, 8.08-10.56) and DLP was 432 mGy·cm (95% CI, 385-478). Compared with 120-kVp FBP, 120-kVp IR significantly reduced CTDIvol (mean difference -8.16 mGy; p < 0.001) and DLP (mean difference -348 mGy·cm; p < 0.001). Heterogeneity was very high for CTDIvol (I²=99.58%) and DLP (I²=99.57%); scanner vendor significantly contributed to this heterogeneity. Pooled diagnostic sensitivity was 79%, specificity 91%, and AUC 0.895. DLR demonstrated promising dose and image-quality improvements, although evidence was limited. CONCLUSION: Advanced reconstruction techniques, particularly IR, can enable substantial radiation dose reduction while maintaining acceptable diagnostic performance. However, substantial heterogeneity, small-study effects, and low certainty of evidence warrant cautious interpretation. Further multicenter studies are needed to establish optimal reconstruction and acquisition strategies. PLAIN LANGUAGE SUMMARY: CT enterography is a scan used to check the small bowel, but repeat scans can give people a high radiation dose. We reviewed 15 studies to see if new image methods could lower this dose while keeping good test results. This study found that iterative reconstruction helped lower radiation while keeping good accuracy, and deep learning methods showed promise, but results varied a lot, and evidence was limited. These findings may help doctors reduce radiation exposure, but more studies at many centers are needed to find the best scan settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prospective evaluation of an optimized low-dose CT enterography protocol for patients with Crohn's disease.European journal of radiology · 2026
- Dose optimization and modeled lifetime attributable cancer risk in brain CT using hybrid statistical iterative reconstructionEgyptian Journal of Radiology and Nuclear Medicine · 2026
- "Quantitative Modeling and Optimization of Radiation Dose in Routine CT Imaging: Balancing Image Quality and Dose Reduction under the ALARA Principle Framework"International Journal of Drug Delivery Technology · 2026
- CT Radiation Dose Reduction With Preserved Diagnostic Performance: How Far Have We Come Over 25 Years?American Journal of Roentgenology · 2026
- Institutional CT dose reduction: A retrospective evaluation of dose indices from 2015-2024.Journal of applied clinical medical physics · 2026
- Intelligent Organ Recognition Technology Combined With an Artificial Intelligence Iterative Reconstruction Algorithm in Contrast-enhanced CT of the Chest, Abdomen, and Pelvis.Academic radiology · 2026