Journal of the mechanical behavior of biomedical materials

A two-stage computational framework for trabecular-bone remodelling: local mechanical signal collection and finite spatial allocation.

Zihao Liu, Simin Li, Juan Du, Vadim V Silberschmidt

Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, United Kingdom. · Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, 300072, China.

Key points

From the paper's conclusion
  • These results support distinguishing the collection of a local mechanical signal from the eligibility, amount and spatial allocation of the resulting tissue change.

Abstract

Mechanically regulated bone adaptation involves collecting stimuli-induced signals from the osteocytes and surface remodelling with basic multicellular units. This study developed a two-stage finite-element framework that simulates these functions at distinct stages. Stage I collects the mechanical signal from the surrounding bone, treating each bone element as a signal source. Stage II combines mechanical eligibility and spatial priority with a finite adaptation capacity and a formation allowance, which was seeded initially and replenished by completed resorption after a delay. Evaluation used six-month longitudinal high-resolution peripheral quantitative computed tomography (HR-pQCT) labels from 206 distal-tibia trabecular subvolumes in nine postmenopausal women. At matched formation counts, the two-stage model, ordering eligible sites based on local mechanical contrast, places formation more precisely than the same model ordered by the absolute collected signal (by 2.06 percentage points) and then a traditional fixed-set-point model; the advantage of ordering about doubled when eligibility was broadened. The ordering advantage preceded divergence of geometry and mechanical fields. A complementary resorption analysis showed a similar advantage. Baseline architecture retained substantial placement information, while mechanical weighting provided additional discrimination. These results support distinguishing the collection of a local mechanical signal from the eligibility, amount and spatial allocation of the resulting tissue change. The framework allows each of these operations to be compared separately in an evolving image-based model.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers