Hyper-viscoelastic characterization of adolescent porcine growth plates under physiological compression.
L Hucke, G Q Teixeira, J Schwer, A M Seitz, A J Gámez, A Huß, N Hammer, A Wittek,
Personalized Biomedical Engineering Laboratory, Department 2: Computer Science and Engineering, Frankfurt University of Applied Sciences, Frankfurt, Germany; Department of Mechanical Engineering and Industrial Design, School of Engineering, Universidad de Cádiz, Cádiz, Spain; Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria. · Institute of Orthopedic Research and Biomechanics, Ulm University Medical Centre, Ulm, Germany; Division of Division of Experimental Orthopedics, Department of Orthopedics, Ulm University Medical Center, Ulm, Germany.
Key points
From the paper's conclusion- Correlation analyses revealed significant associations between relaxation-related energy dissipation and histological features such as growth plate thickness and chondrocyte column orientation (p < 0.05).
Abstract
The mechanical behavior of the growth plate plays a central role in longitudinal bone growth, yet constitutive material descriptions suitable for finite element modeling remain poorly defined. In particular, hyperelastic material parameters for growth plate tissue have not previously been reported. In this study, unconfined compression tests were performed on porcine growth plate samples from the proximal femur, distal femur, and proximal tibia using a multistep stress-relaxation protocol. Specimens were successively compressed to predefined target forces, and the resulting deformation was maintained for 300 s at each step to record stress relaxation and estimate the equilibrium stress. Digital image correlation was employed to measure deformation directly at the growth plate throughout loading and relaxation. Equilibrium responses were characterized using a three-term Yeoh hyperelastic model, while time-dependent behavior was described by a two-term Prony series. The applied loading protocol covered physiologically relevant joint force magnitudes and resulted in compressive strains ranging from 5.6% to 35%. Significant differences in hyperelastic material response were observed between growth plate types, defined by their anatomical site (proximal femur, distal femur, and proximal tibia; p < 0.05), whereas no consistent effects of medial-lateral location or individual specimens were detected. Viscoelastic parameters showed limited variability across anatomical location. Correlation analyses revealed significant associations between relaxation-related energy dissipation and histological features such as growth plate thickness and chondrocyte column orientation (p < 0.05). These results provide the first experimentally derived hyperelastic and viscoelastic material parameters for growth plate tissue and establish a computationally efficient constitutive framework for finite element modeling of growth plate mechanics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical material characterization of the equine accessory carpal bone: a constitutive modelingCurrent Directions in Biomedical Engineering · 2026
- Characterization and modeling of the mechanical behavior of porcine pancreatic parenchyma.Journal of the mechanical behavior of biomedical materials · 2026
- Structural and mechanical insights into the extracellular matrix of the aging human lacrimal gland for tissue engineering applications.Acta biomaterialia · 2026
- Biomechanical, Structural, and Composition Characterization of the Vertebra‐Disc InterfaceJOR SPINE · 2026
- Divergent trajectories of structural accrual and matrix-level mechanical properties during alveolar bone maturation.Calcified tissue international · 2026
- Discordance among skeletal maturity indicators: sources, interpretation, and clinical implications.Frontiers in pediatrics · 2026