Holmes-Mow type hyperelasticity fitting for parallel plate compression of multicellular spheroids.
Syed Hasan Askari Rizvi, Myoung Hwan Kim, Yi Xiang, Emmie J Yao, Grace Y Lu, Emma L Berman, Shaochen Chen, Ibrahim T Ozbolat,
Engineering Science and Mechanics Department, Penn State University, University Park, PA, 16802, USA; The Huck Institutes of Life Sciences, Penn State University, University Park, PA, 16802, USA. · The Huck Institutes of Life Sciences, Penn State University, University Park, PA, 16802, USA; Department of Biomedical Engineering, Penn State University, University Park, PA, 16802, USA.
Key points
From the paper's conclusion- We experimentally performed parallel plate compression testing of human lung fibroblasts (HLF) spheroids, with a nominal size of 300 μm.
Abstract
Multicellular spheroids, widely used tissue building blocks in the emerging fields of bioprinting and biofabrication, are key prototypes to study tissue mechanics. Here, we present the characterization of a compressible hyperelasticity constitutive model based on Holmes-Mow type elasticity for multicellular spheroids. We implemented the constitutive model in a Finite Element (FE) piece of software, verified the FE implementation, and simulated the compression test of a spheroid between two parallel plates. We found dimensionless numbers-dimensionless load, lateral diameter stretch ratio, and compression ratio-associated with the constitutive model and the spheroid geometry. Using parametric sweeps in FE calculations, we were able to fit polynomial relationships for these dimensionless numbers. We experimentally performed parallel plate compression testing of human lung fibroblasts (HLF) spheroids, with a nominal size of 300 μm. We then fit the obtained polynomial relationship of dimensionless numbers to the experimental dataset to find material parameters of HLF spheroids associated with the proposed constitutive model. After fitting our model to the reported experiments, we performed a numerical simulation of micro-pipette aspiration of a spheroid to relate the aspiration pressure to the spheroid deformation. We highlighted the advantages of the parallel plate compression testing over a micro-pipette aspiration technique for mechanical characterization. The work we present herein provides a framework for the mechanical characterization of spheroids using parallel plate compression and the above-mentioned constitutive model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of initial cell number, maturation stage, and compressive strain on the viscoelastic response of normal human dermal fibroblast spheroids.Journal of the mechanical behavior of biomedical materials · 2026
- Optimal design for multi-compartment cell elasticity estimation using AFM and super-resolution imagingComputer Methods and Programs in Biomedicine · 2026
- Nonlinear Hyperelastic Characterization of the PolyJet Digital Anatomy Material Library and Selection Methodology for Tissue-Mimicking Anatomical Models.Journal of biomedical materials research. Part B, Applied biomaterials · 2026
- Multiscale mechanical analysis of live breast cancer spheroids by micro-compression and Brillouin imaging.Journal of microscopy · 2026
- Hybrid 3D Biofabrication Using a Combination of an In Situ Mechanical Fiber Spinning Method and Extrusion‐Based 3D (Bio) Printing for Skeletal Muscle Tissue Engineering ApplicationsAdvanced Materials Technologies · 2026
- Indenting multicellular spheroids with various tip geometriesEuropean Biophysics Journal · 2026